INSTRUMENTATION
SERVICE MANUAL NUMBER 24
Page 4D-12
90-861327--1 OCTOBER 1999
Switches
Ignition Key Switch
TESTING
CAUTION
Disconnect battery cables from battery before testing ignition key switch with wires
still connected to switch.
1. Disconnect battery cables, if testing ignition key switch with wires connected to switch.
2. With key switch in OFF position, there should be no continuity between switch terminals.
3. With key switch in RUN position, continuity will exist between switch terminals B to I.
There should no continuity between terminal S and any other terminals.
4. With key switch in START, continuity will exist between terminals B to I and B to S.
5. Terminals are to make contact at angles shown and to stay in contact condition as switch
is rotated toward START.
6. If ignition key switch tests bad, disconnect wire connections and remove switch. Test
switch again, as in Steps 2.-5. If switch tests good, wiring in harness is bad. There should
be no continuity between any harness wires with key switch removed.
72760
B
S
I
a
b
f
c
d
e
Key View
Back View
a -
Key
b -
Off
c -
Continuity, B to I Terminals
d -
Run
e -
Continuity B to S Terminals
f -
Start
Index