8.  Bulk Erase Configuration Memory: 

The bulk erase function can be used for the following purposes: 

  Erase all configuration and cardholder database (sanitize board). 

  Update OEM default parameters after OEM code has been changed.  

  Recover from database corruption causing MS-ICS board to continuously reboot.   

 
If clearing the memory does not correct the initialization problem, contact technical support. 
 

Bulk Erase Steps: 

Do not remove power during steps 1-8.  

1.  Set S1 DIP switches to: 1 & 2 "ON", 3 & 4 "OFF". 
2.  Apply power to the MS-ICS board. 
3.  Watch for LEDs 1 & 2 and 3 & 4 to alternately flash at a 0.5 second rate. 
4.  Within 10 seconds of powering up, change switches 1 or 2 to "OFF".  If these switches are not changed, 

the MS-ICS board will power up using the OEM default communication parameters. 

5.  LED 2 will flash indicating that the configuration memory is being erased. 
6.  Full memory erase takes up to 60 seconds. 
7.  When complete, only LEDs 1 & 4 will flash for 8 seconds. 
8.  The MS-ICS board will reboot 8 seconds after LEDs 1 & 4 stop flashing (no LEDs are on during this time). 

 

9.  IT Security 

When installing the MS-ICS, it is important to ensure that it done in a secure manner. 

Upon installation, the user accounts to the web configuration page should be created with secure passwords, 
and that all DIP switches are in the off position for the normal operating mode.  The MS-ICS is shipped from 
the factory with a default login account, which is enabled when DIP 1 is moved from OFF to ON.  The default 
login user name and password will be available for five minutes once enabled.  Therefore, it is important that at 
least one user account is defined, and the DIP switches are set to OFF before the MS-ICS is commissioned.  It 
is also highly recommended not to configure the MS-ICS with an IP address that is accessible from the public 
Internet. 

To further enhance network security, options are available to disable SNMP, Zeroconf discovery, as well as the 
web configuration module itself.  Additionally, data encryption can also be enabled over the host communication 
port. 

 

 

Summary of Contents for MS-ICS

Page 1: ...n ribbon cable up to two MS ACS are supported Standard Mercury remote serial I O panels may be connected to the external 2 wire RS 485 multi drop communication bus MS ICS J5 1 4 3 2 S1 ON D7 1 2 3 4 5 6 J8 TR TR GND TB2 4 1 BATTERY BR CR2330 REPLACE ANNUALLY GND TMP GND PFL GND BAT TB1 6 1 BT1 3V CR BR2330 S2 J4 J2 12VDC J1 1 1 75 44 55 6 11 155 19 8 58 218 01 J5 CONNECTION FOR LANTRONIX MICRO125 ...

Page 2: ...38 400 baud no encryption no flow control 3 Input Power Wiring The MS ACS requires 12 Vdc for input power and is connected to J2 Pins 1 and 2 are connected to ground and pin 3 is connected to 12 Vdc Observe POLARITY on 12 Vdc input J2 mates with the following housing and uses two crimp contacts Housing Molex 39 01 4030 Crimp contact Molex 39 00 0047 22 28 gauge 39 00 0039 18 24 gauge 4 Cabinet Tam...

Page 3: ...s 1 3 and 5 are turned ON for approximately 1 5 seconds after the hardware initialization has completed then the application code is initialized The amount of time the application takes to initialize depends on the size of the database about 3 seconds without a card database Each 10 000 cards will add about 3 seconds to the application initialization When LED s 1 through 4 flash at the same time d...

Page 4: ... seconds 7 When complete only LEDs 1 4 will flash for 8 seconds 8 The MS ICS board will reboot 8 seconds after LEDs 1 4 stop flashing no LEDs are on during this time 9 IT Security When installing the MS ICS it is important to ensure that it done in a secure manner Upon installation the user accounts to the web configuration page should be created with secure passwords and that all DIP switches are...

Page 5: ...tice Warranty Mercury Security warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment Mercury Security assumes no responsibility for products damaged by improper handling or installation This warranty is limited to the repair or replacement of the defective unit There are no expressed...

Reviews: