2. Disconnect the flush connector from the fitting on the bottom cowl.
28726
3. Thread a water hose into the flush fitting.
28727
4. Turn on the water tap (1/2 maximum) and let the water flush through the
cooling system for about 15 minutes.
5. When flushing is complete, turn off water and disconnect the water hose.
6. Install the flushing connector to the fitting on the bottom cowl. Tighten the
connector securely.
Cowl Removal and Installation
COWL REMOVAL
IMPORTANT: Most maintenance points are accessible by removing the top
cowl only.
1. Pull up on the top cowl lock latch.
28946
MAINTENANCE
eng
87