AUDIBLE CONTINUITY
RANGE
DESCRIPTION
Built-in buzzer sounds if resistance is
less then 30
±
20
Ω
OVERLOAD PROTECTION:15 seconds maximum
220Vrms.
DC CURRENT
OVERLOAD PROTECTION: 500mA 250V fuse (10A range
infused).
MEASURING VOLTAGE DROP: 200mV
RESISTANCE
RANGE
RESOLUTION
ACCURACY
200Ω
0.1Ω
±(1.0% of rdg +10D)
2000Ω
1Ω
20KΩ
10Ω
200KΩ
100Ω
2000KΩ
1KΩ
±(1.0% of rdg +4D)