                                                600.105UK User Manual

 

 

MAXIMUM OPEN CIRCUIT VOLTAGE: 3V. 
OVERLOAD PROTECTION: 15 seconds maximum 

220Vrms. 
 

OPERATING INSTRUCTIONS 

DC & AC VOLTAGE MEASUREMENT 

1.

 

Connect 

red test lead to “VΩmA” jack, Black lead to 

“COM” jack.

 

2.

 

Set RANGE switch to desired VOLTAGE position, if the 

voltage to be measured is not known beforehand, set 
the switch to the highest range and reduce it until a 

satisfactory reading is obtained. 

3.

 

Connect test leads to device or circuit being 
measured. 

4.

 

Turn on power of the device or circuit being measured 
and the voltage value will appear on the Digital 

Display along with the voltage polarity. 

 

DC CURRENT MEASUREMENT 

1.

 

Red lead to “VΩmA”. Black lead to “COM” (for 

measurements between 200mA and 10A connect red 

lead to “

10

A” jack with fully depressed.)

 

2.

 

Set RANGE switch to desired DCA position. 

3.

 

Open the circuit to be measured, and connect test 
leads in SERIES with the load and with current to 
measure. 

4.

 

Read current value on Digital Display. 

5.

 

Additionally, “

10

A” function is designed for 

intermittent use only. Maximum contact time of the 

test leads with the circuit is 15 seconds, with a 
minimum intermission time of 15 mins between tests. 

Summary of Contents for 600.105UK

Page 1: ...Please read this manual thoroughly and ensure all contents are fully understood before use of the apparatus WARNING MTN01 Network Digital Multimeter Item Ref 600 105UK EN61010 1 2010...

Page 2: ...ltage as marked on the meter between the terminals or between any terminal and grounding The rotary switch should be placed in the right position and no changeover of range should be made during measu...

Page 3: ...e meter and accidents A soft cloth and mild detergent should be used to clean the surface of the meter on a regular basis No abrasives or solvents should be used to prevent the surface of the meter fr...

Page 4: ...LCD 3 digits 1999 count 0 5 high Polarity Automatic indicated minus assumed plus Measure method double integral A D switch implement Sampling speed 2 times per second Over load indication 1 is display...

Page 5: ...www avsl com 600 105UK User Manual Overview COM jack V mA jack 10A jack hFE socket LCD RANGE switch Cable test remote unit...

Page 6: ...for 1 year 23 5 less than 80 RH DC VOLTAGE OVERLOAD PROTECTION 220V rms AC for 200mV range and 500V DC or 500Vrms for all ranges AC VOLTAGE RESPONSE Average responding calibrated in rms of a sine wav...

Page 7: ...sounds if resistance is less then 30 20 OVERLOAD PROTECTION 15 seconds maximum 220Vrms DC CURRENT OVERLOAD PROTECTION 500mA 250V fuse 10A range infused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE R...

Page 8: ...rn on power of the device or circuit being measured and the voltage value will appear on the Digital Display along with the voltage polarity DC CURRENT MEASUREMENT 1 Red lead to V mA Black lead to COM...

Page 9: ...est lead to the anode of the diode to be measured and black test lead to cathode 4 The forward voltage drop in mV will be displayed If the diode is reversed the figure 1 will be shown TRANSISTOR hFE M...

Page 10: ...6 7 8 G RJ45 Remote unit 1 2 3 4 5 6 7 8 G Main unit 1 2 3 4 5 6 RJ11 Remote unit 1 2 3 4 5 6 FAULT DESCRIPTIONS 1 If one cable is open circuit eg no 3 then the no 3 LED on both units wont illuminate...

Page 11: ...remove the 2 screws in the bottom of the case simply remove the old and replace with a new one Be careful to observe polarity ACCESSORIES Operator s instruction manual Set of test leads red and black...

Reviews: