Replace the battery as soon as the battery indicator   appears. With a 

low battery, the meter may produce false readings that can lead to 
electric shock and personal injury. 

 

Remove the connection between the testing leads and the circuit being 

tested and turn the meter power off before opening the meter case. 

 

The internal circuit of the meter shall not be altered at will to avoid 

damage of the meter and any accident. 

 

A soft cloth and mild detergent should be used to clean the surface of 

the tester on a regular basis. No abrasive and solvent should be used 

to prevent the surface of the tester from corrosion or damage. 

 

The tester is suitable for indoor use only. 

 

Turn the tester power off when it is not in use and take out the battery 

when not using for a long time. Check the battery regularly; replace the 
battery immediately if any signs of leaking appear. Battery acid will 

damage the tester. 

 

General Specifications 

 

Max display:  

 

LCD (1999 count) 1.25 inch 

Polarity:    

 

Automatic, indicated minus, assumed plus 

Measure method:    

double integral A/D switch implement 

Sampling speed:    

2 times per second 

Over-load indication:  

“1” is displayed 

 

Operating Environment:  

0ºC-40ºC, at <75%RH  

Storage Environment:  

-10ºC-50ºC, at <85%RH 

Power:   

 

9Vdc (1 x PP3 battery supplied) 

Low battery indication:  

“ ”

 

Dimensions:  

 

190 x 85 x 35mm   

Weight:    

 

322g (including battery) 

 
 

 

 
 

 

Summary of Contents for 600.107UK

Page 1: ...Item ref 600 107UK MTN02 Digital Network Multimeter User Manual...

Page 2: ...e as marked on the tester between the terminals or between any terminal and grounding The rotary switch should be in the right position and no changeover of range shall be made while measurement is co...

Page 3: ...be used to prevent the surface of the tester from corrosion or damage The tester is suitable for indoor use only Turn the tester power off when it is not in use and take out the battery when not using...

Page 4: ...www avsl com 600 107UK Overview...

Page 5: ...ed for 1 year 23 C 5 C less than 70 RH DC Voltage RANGE RESOLUTION ACCURACY 200mV 0 1mV 0 8 of rdg 5D 2V 1mV 20V 10mV 0 5 of rdg 2D 200V 100mV 600V 1V 1 0 of rdg 5D Input Impedance 10M Overload Protec...

Page 6: ...ated in rms of sine wave Max Input voltage 600V AC rms DC Current RANGE RESOLUTION ACCURACY 20mA 10uA 0 8 of rdg 5D 200mA 100uA 10A 10mA 1 5 of rdg 3D Overload Protection 20mA and 200mA ranges F0 5A 2...

Page 7: ...ave Resistance RANGE RESOLUTION ACCURACY 200 0 1 1 5 of rdg 3D 2K 1 1 5 of rdg 3D 20k 10 200k 100 2M 1k 1 5 of rdg 3D 20M 10k 1 5 of rdg 3D Open Circuit Voltage about 0 25V Overload Protection 250V DC...

Page 8: ...on Digital Display along with the voltage polarity Please note In small range the meter may display an unstable reading when the test leads have not been connected to the load to be measured It is no...

Page 9: ...s the over range symbol 1 a higher range must be selected RESISTANCE MEASUREMENT 1 Connect red lead to V black lead to COM 2 Set the range switch to desired range 3 If the resistance being measured is...

Page 10: ...SUREMENT 1 Connect red lead to V mA black lead to COM 2 Set RANGE switch to position 3 Connect the red test lead to the anode of the diode to be measured and black test lead to cathode 4 The meter wil...

Page 11: ...it the LED s of main unit will light in turns and the LED s of the remote unit will have two or more lights out MISWIRE REVERSAL The LED s of the main unit will illuminate in sequence but the LED s of...

Page 12: ...the test leads have been disconnected and power is off 2 Loosen the 2 screws under the prop stand with a suitable screwdriver and remove the case cover 3 The meter is powered by a single 9V PP3 batte...

Page 13: ...ment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your local council guidelines Errors and omissions exc...

Reviews: