350.137UK User Manual
SD102P Specification:
Battery
1 x 9V PP3 (supplied)
Alarm output
85dB/3m
Operation temperature
-10°C ~+40°C
Quiescent current
≤
12µA
Dimensions
34 x 101mmØ
Weight
136g (with battery)
Installation:
1.
Choose an appropriate position to install the alarm on a ceiling away from obstructions.
2.
Use the screws and plugs provided to secure the installation panel securely to the ceiling.
3.
Align the 2 locating slots in the smoke detector with the 2 tags on the installation panel and rotate it
clockwise until it locks into position.
Testing and usage:
1.
Turn the smoke detector anti-clockwise to remove it from the installation panel.
2.
Insta
ll the 9V battery supplied and ensure it’s clipped behind the red security arm at the side of the
panel.
3.
4.
Align the 2 locating slots in the smoke detector with the 2 tags on the installation panel and rotate it
clockwise until it locks into position.
Locating slot
Tag
9V Battery
Security Arm
Locating slot
Test/Hush
Warning LED
Sounder