IMPoRtAnt 

SAFetY InStRUCtIonS

•  Read the instructions.

•  Keep these instructions.

•  Follow all instructions.

•  Do not use this apparatus near water.

•  Clean only with a dry cloth.

•  Install only in accordance with manufacturer’s 

instructions.

•  Refer all servicing to approved service personnel.

This apparatus has been designed with Class 
1 construction and must be connected to a 
mains socket outlet with a protective earth 
connection (the third grounding prong).

Do not defeat the safety purpose of the 
polarized or grounding-type plug. A polarized 
plug has one prong wider than the other. A 
grounding type plug has two blades and a 
third grounding prong. The wide blade or the 
third prong are provided for your safety. If the 
provided plug does not fit into your outlet, 
consult an electrician for replacement of the 
obsolete outlet.

WARNING: TO REDUCE THE RISK OF FIRE 
OR ELECTRIC SHOCK, DO NOT EXPOSE THIS 
APPARATUS TO RAIN OR MOISTURE

This apparatus uses a single-pole power 
switch. As a result it is not isolated from AC 
mains power when switched off at the rear 
panel. The apparatus may be isolated from 
mains power either by unplugging the power 
connector from the rear of the unit, or by 
unplugging the connector at the opposing 
end of the power cord or cable from its supply 
outlet. As a result, either or both of these 
connectors should remain accessible.

Safety warnings

•  Do not expose the unit to dripping or splashing.

•  Do not place any object filled with liquid, such 

as a vase, on the unit.

•  Do not place naked flame sources, such as 

lighted candles, on the unit.

To avoid interference

Do not position the unit:

•  Near strong magnetic radiation.

•  Near to a television, or where connecting cables 

may be subject to or cause interference.

To avoid overheating

•  Leave at least 10cm around the equipment to 

ensure sufficient ventilation.

Do not position the product:

•  In direct sunlight.

•  Near heat sources, such as a radiator.

•  Stacked with any other audio products other 

than in a properly ventilated rack, as the heat it 

generates may damage the other products.

The sides and top of the C51 case contain 
venting holes for the internal heatsinks which 
should not be obstructed. Ensure that air can 
flow around them. The product normally runs 
warm to the touch when not in standby.

Warning: The C51 is moderately heavy; take 
care when lifting it.

Radio interference

FCC Warning: This equipment generates 
and can radiate radio frequency energy 
and if not installed and used correctly in 
accordance with our instructions may cause 
interference to radio communications or radio 
and television reception. It has been type-
tested and complies with the limits set out in 
Subpart J, Part 15 of FCC rules for a Class B 
computing device. These limits are intended 
to provide reasonable protection against such 
interference in home installations.

EU: This product has been 
designed and type-tested to 
comply with the limits set out in 
EN55013 and EN55020.

Summary of Contents for C51

Page 1: ... Please review this manual carefully before contacting Technical Support PRODUCT OWNERS Please contact your authorised Meridian dealer for product or installation questions Meridian C Series Installation Components C51 5ch x 2 bass treble Active Speaker Power Unit Installation and Operation Manual ...

Page 2: ...This page intentionally left blank ...

Page 3: ... review the instructions in the following pages of this manual to help insure a smooth installation and a happy customer Copyright 2007 Meridian Audio Limited No part of this document may be copied photocopied translated or reproduced to any electronic medium or machine readable form without prior consent in writing from Meridian Specifications subject to change without notice All Rights Reserved ...

Page 4: ...arnings Do not expose the unit to dripping or splashing Do not place any object filled with liquid such as a vase on the unit Do not place naked flame sources such as lighted candles on the unit To avoid interference Do not position the unit Near strong magnetic radiation Near to a television or where connecting cables may be subject to or cause interference To avoid overheating Leave at least 10c...

Page 5: ...n If you wish to dispose of this product please do so in accordance with applicable national legislation or other rules in your country for the treatment of old electrical and electronic equipment Accessory Kit The following items are supplied with C51 Powered Crossover Amplifier unit 1 This manual 1 Power Cord Service and guarantee Service The Meridian components have been carefully designed to g...

Page 6: ...rotection circuitry is included The C51 has soft start fan output and trigger input The front panel includes five sockets for installation of the crossover cards which can be accessed by unscrewing the transparent smoked access cover Front panel indicators take the form of blue LEDs for main power and for each channel arranged in high low pairs so that the status can be instantly assessed The rear...

Page 7: ...d warranty Mounting The C51 is primarily designed to be mounted in a standard 19in rack Feet are provided for free standing operation these should not be present if the unit is to be rack mounted EXCESSIVE HEAT MAY CAUSE THE UNIT TO MALFUNCTION OR SHORTEN PRODUCT LIFE Follow regular installation rules for proper ventilation Be sure rack location has adequate ventilation Allow a minimum of 1U rack ...

Page 8: ...bles for each speaker connected to the BASS and and the TWEETER and terminals Plug the crossover module supplied with each Active Installation Loudspeaker into the appropriate crossover bay on the front panel of the C51 and re fit the acrylic cover Ensure that the card is correctlly seated and that the correct card for the speaker is in the appropriate slot Each crossover card includes indicator l...

Page 9: ...ot illuminated a fault condition is indicated A further blue LED is situated next to the Standby button and illuminates when the unit is in standby indicating that the unit is powered When this light is illuminated the channel indicators should be extinguished A blue LED indicates when the unit has been shut down as a result of overheating In an overtemperature situation the entire unit will enter...

Page 10: ...nits move when the C51 is switched on or off This is normal as the amplifier electronics settle The sound from one or more speakers is either muffled lacking in HF or thin lacking in bass Check that the crossover cards have been correctly inserted and in particular that the type of crossover card in each bay matches the type of loudspeaker connected to the corresponding output channel Each crossov...

Reviews: