The BlueFIRE Monitor displays pressures created by 
the BlueFIRE Inflation Syringe. The BlueFIRE Syringe 
is connected to the Monitor via Bluetooth wireless 
technology. In addition to displaying pressure pa-
rameters in ATM (atmospheres), psi (pounds per 
square inch), mmHg (millimeters of mercury), or Bar, 
the BlueFIRE Monitor displays duration of pressur-
ization in minutes and seconds, time elapsed since 
last pressurization, and indicates when a negative 
pressure has been reached. The Monitor also stores 
an activity log of the inflation pressures reached 
during the procedure, and has the capability to 
email or print the activity logs.

The BlueFIRE Inflation Syringe is a 30mL disposable 
device with an integral pressure transducer, thread-
ed plunger assembly with lock/release bar, a flexible 
high-pressure extension tube, and a three-way stop-
cock. The BlueFIRE Syringe generates positive and 
negative pressure over a range of -1 to +40ATM/BAR 
(-1 to 588 PSI), and sends pressure information to the 
BlueFIRE Monitor via Bluetooth wireless technology.

PRINTER

ENGLISH

BlueFIRE_UserManual2.indd   3

10/20/2017   2:51:24 PM

Summary of Contents for BlueFIRE

Page 1: ...EN USER MANUAL FR IT DE ES PT PTBR NL SV DA EL TR PL CS BG HU BlueFIRE_UserManual2 indd 1 10 20 2017 2 51 24 PM...

Page 2: ...s may result CAUTION To ensure Monitor stability use BlueFIRE mounting accessories only CAUTION The use of accessories sensors and cables other than those specified may result in in creased emission a...

Page 3: ...ure has been reached The Monitor also stores an activity log of the inflation pressures reached during the procedure and has the capability to email or print the activity logs The BlueFIRE Inflation S...

Page 4: ...thumb screw until the socket fits onto the ball on the clamp position the Monitor then tighten the thumb screw 2 Table Mounting The BlueFIRE table mount part number IN10TABLE may be inserted into the...

Page 5: ...onnect Manually and select the Syringe from the list Note To scan hold the Syringe QR code steady and aligned within the red box on the screen If it does not immediately scan try slowly rotating the S...

Page 6: ...d other contaminants with a cloth dampened with water isopropyl alcohol or mild detergent Do not spray the Monitor directly with the cleaning solution MENU FUNCTIONS Note Menu Functions are not availa...

Page 7: ...printer after the procedure Note The Bluetooth printer must be set up SETTINGS Access settings by pressing this icon Press the symbol to add email addresses to the address list These email addresses w...

Page 8: ...Rules These limits are designed to provide rea sonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate...

Page 9: ...ENGLISH End of English Manual BlueFIRE_UserManual2 indd 9 10 20 2017 2 51 29 PM...

Page 10: ...BlueFIRE_UserManual2 indd 10 10 20 2017 2 51 29 PM...

Page 11: ...BlueFIRE_UserManual2 indd 11 10 20 2017 2 51 29 PM...

Page 12: ...BlueFIRE_UserManual2 indd 12 10 20 2017 2 51 29 PM...

Reviews: