System Saver Series Installation Criteria
Operating Parameters
Requirements
Pressure requirements
Maximum pressure
140 psi
Minimum governor cut-out
pressure
115 psi
Governor range
15 to 25 psi (cut-out — cut-in)
Flow capacity
Compressor rating
25 cfm maximum
Compressor on-time
Normal running
2 minutes maximum
Occasional (three times per
day maximum)
7 minutes
Compressor unloaded
time
Minimum for purge cycle
20 seconds
Maximum duty cycle
Compressor on-time ÷ total
running time
30%
Discharge line
Temperature at inlet port
determines required length
and diameter.
To minimize the likelihood of a discharge line blockage during
cold climate operation, it is recommended that for discharge lines
exceeding 9 feet in length, a minimum of 3 feet of 1/2-inch thick
closed-cell polyethylene pipe insulation be used at the connection
to the air dryer.