Appendix III
Special Applications
MM-34
Page 28
Revised 11-02
Appendix III
Special Applications
Holset E-Type Compressor
Systems
When a System Saver Series air dryer is used with
a Holset E-type compressor system, an external
Econ valve is used.
Figure A.1
.
On the 1200E Series, an integral Econ function
eliminates the need for the external Econ valve.
Figure A.2
.
If you are currently using a System Saver Series
air dryer WITHOUT an Econ valve, and your
application requires one, Meritor WABCO
recommends installing the System Saver 1200E.
Figure A.1
PURGE
VALVE
(EXHAUST)
COMPRESSOR
DISCHARGE
LINE
COMPRESSOR
COMPRESSOR
INTAKE LINE
PRESSURE-
CONTROLLED
CHECK VALVE
SUPPLY
TANK
SYSTEM
RESERVOIRS
ONE-WAY
CHECK
VALVE
DRYER
INLET
PORT
UNLOADER
LINE
RESERVOIR
TO GOVERNOR
LINE
1800
1200
ECON
VALVE
CHECK VALVE
(FLOW DIRECTION)
BACKFEED
LINE
SUPPLY
LINE
SIGNAL
LINE
COMPRESSOR
DISCHARGE
LINE
DRYER
OUTLET
PORT
REGENERATION
VALVE
GOVERNOR
CONTROL
(PURGE)
PORT
SYSTEM SAVER SERIES
REGENERATION
STYLE AIR DRYER
UNLOADER
PORT