background image

DOCUMENT NON CONTRACTUEL

SPECIFICATIONS SUBJECT TO MODIFCAIONS 

M E R L A U D

9 rue de La Briqueterie - P.A.E. des FAUVETTES - 95330 DOMONT (FRANCE)
Tel. 01 39 91 77 78 - Fax 01 39 91 90 66 - 

www.merlaud.com

- merlaud@merlaud.com

e r l a u d

NOTICE D’UTILISATION ET DE DEPANNAGE

/ OPERATION & MAINTENANCE INSTRUCTIONS

AMPLIFICATEURS

AMPLIFIERS

DO3-51-AMB D-V120308

Page 8/8

Mettre une modulation 0dB sur l'entrée de l'ampli
LED / INDICATEUR 

ETAT NORMAL 

 DEFAUT

CAUSE

HP

(1)Led  clignotante : calibration en 
cours                                            
(2) Led éteinte :Ligne hp calibrée

Led allumée : ligne hp non calibrée

(1) Ligne Hp non connectée                            
(2) Ligne HP  hors limite surchargée ou peu 
chargée                                                        
(3) Ligne HP en court circuit 

Température

Led allumée:  pas de surchauffe 
température dissipateur  < 95°C

Led allumée  :surchauffe :  thermostat  
ouvert 
température de coupure  > 95°C  atteinte 
Température de rétablissement < 80°C 

(1) Ventilation insuffisante                               
(2) Ligne HP   surchargée                               
(3) Ligne HP en court circuit                           
(4)  Thermostat en panne (bloqué en cont

Terre

Led éteinte: Pas de fuite à la terre

Led allumée : Fuite à la terre

Ligne HP non isolée par rapport à la terre 

Secteur

Led allumée :  présence secteur

Led éteinte :Pas d'alimentation secteur

(1)  amplificateur non connecté  au secteur      
(2)  Fusible secteur coupé 

Batterie

Led  allumée : présence Batterie

Led éteinte : Pas d'alimentation batterie
Vérifier le fusible de l'alimentation 
batterie (en interne)

(1)  amplificateur non connecté  à la batterie    
(2)  Fusible batterie coupé 

BF

Led  s'allume :Présence de la 
modulation en sortie.(bornier V4) E

Led éteinte :Pas de signal  BF en sortie 
d'ampli.(bornier V4)

(1) Pas de signal à l'entrée                             
(2) thermostat est en mode  "contact ouvert "

BF

Led  s'allume en fonction du signal 

Led s'allume mais pas de signal  BF sur 
les bornes de sortie (bornier V4) alors 
que le signal existe entre la borne N ° 4 
du bornier V4 et le point T100 (sortie 
100V du transfo de sortie)

La liaison carte de surveillance est 
défectueuse 

Saturation

Led  éteinte : état normal 

led allumée : signal de sortie saturé

 signal sur l'entrée de l'ampli trop  fort

tension entre B et M

0,48V DC

Ecart +/- 5 %

(voir fig 3) 

tension entreCet M

38V DC

Ecart +/- 5 %

(voir fig 3) 

Apply 0dB Audio Signal on Input
LED / INDICATOR

NORMAL STATUS

FAULT

REASON

Speaker line

(1)blinking : calibration in 
progress                              
(2) Off :Speaker line 
calibrated

on : speaker line uncalibrated

(1) speaker line unplugged or open circuit                 
(2) speaker line overload or underload (out of 
bounds)                                                                 
(3) short circuit on speaker line

Temperature

on:  no overheating 
heat sink temperature  < 
95°C

g

p

circuit 
operating temperature  > 95°C  
exceeded 
reset temperature < 80°C 

(1) insufficient ventilation                                         
(2) Speaker line overlaod                                         
(3) short circuit on speaker line                               
(4) Faulty Thermostat (stuck in open contact)

Earth

off : no earth leakage

on : earth leakage

speaker line not insulated from earth

AC

on :  AC power supply OK

off : AC fault

(1)  Amplifier not connected to AC power supply       
(2)  AC Fuse blown up or absent 

Battery

on :  Battery OK

off : Battery fault
Check fuse for battery power supply 
(internal)

(1)  Amplifier not connected to Battery power supply 
(2)  Battery Fuse blown up or absent 

Audio Signal

on :Output signal 
broadcasting.(V4 connector 
fig 2)

off :no Audio signal coming from 
amplifier output.(V4 connector fig 2 ).

(1) No input signal                                                  
(2) Thermostat in "open contact mode "

Audio Signal

lights varying in function of  
output signal 

Led is on but no audio signal coming 
from amplifier output (V4 connector) 
while the  a signal between plot N ° 4 
from V4 connector and T100 point 
(100V output on from transformer)  is 
present (see fig 3)

Link thru Surveillance Board is faulty

Saturation

off : normal status

on : saturated output signal

input signal too high 

voltage between B & M

0,48V DC

Tol/- 5 %

(see fig 3)

voltage between C & M

38V DC

Tol/- 5 %

(see fig 3)

AMB 80 D

2478

AMB 160 D

2479

AMB 240 D

2499

Summary of Contents for AMB 80 D

Page 1: ... mountable w kit AMB 80 D AMB 160 D AMB 240 D Code 2478 2479 2499 Puissance nominal Nominal Power 80W 160W 240W Sortie HP Speakers Line Output 100V 100V 100V Alimentation Power supply 240V AC 24VCC 240V AC 24VCC 240V AC 24VCC Bande passante Bandwidth 50 20000Hz 50 20000Hz 50 20000Hz Distortion Harmonique Harmonic Distorsion 0 5 0 5 Hz 1 Sensibilité Sensitivity 0dB 10KΩ 0dB 10KΩ 0dB 10KΩ Rapport si...

Page 2: ...Défaut Alimentation ou surchauffe Température 7 Etat des lignes Haut parleurs PANNEAU AVANT FRONT PANEL Fig 1 1 2 3 4 5 6 7 1 Peak Led 2 Normal Operation Led 3 Battery Led 4 On Off mains Led 5 Ground faulty 6 Power supply faulty or overheating 7 Speaker line status PANNEAU ARRIERE REAR PANEL V0 Embase secteur V2 Embase Femelle XLR Entrée Signal Audio V3 Embase Femelle DB9 Télécontrôles V4 Bornier ...

Page 3: ... 5 Masse 6 Défaut général Option 7 Rétablissement RL Option 8 Entrée signal Audio 9 Entrée signal Audio V4 Bornier à pression 1 Alim batterie 24 Volt 2 Alim batterie Masse 3 Sortie HP 0 Volt 4 Sortie HP 100 Volt V0 V0 Mains socket Power supply socket with built in fuse 3 15A V2 Female XLR socket 1 Ground 2 Audio signal Input 3 Audio signal Input V3 Female DB9 socket 1 Rx 2 Tx 3 Rx 4 Tx 5 Common re...

Page 4: ... D V120308 Page 4 8 Temp Défaut Terre Sous tension secteur Mod Normal modul Max Sous tension Batterie Carte PAV Calibrage et CO CC ligne HP A B C D HP CAVALIERS JUMPERS CONFIGURATION CONFIGURATION Fig 3 A B C D HP CAVALIERS JUMPERS PAV AMPLI SEUL Fig 4 A B PAV C D HP A B PAV C D HP N 1 A B PAV C D HP N 0 A B PAV C D HP N 2 A B PAV C D HP N 3 A B PAV C D HP N 4 A B PAV C D HP N 5 A B PAV C D HP N 6...

Page 5: ...injection permanente d une fréquence de 20KHZ à l entrée à partir d une source externe produisant une tension de 15V à la sortie de l amplificateur 3 2 Affichage de l Etat des défauts 3 2 1 Défauts affichés sur la face avant de l ampli Led 7allumée indique au moins un des défauts suivants Panne amplificateur Ligne HP en court circuit ligne HP en circuit ouvert variation de l impédance de ligne dan...

Page 6: ... à préciser si possible La précision de la mesure dépendra de la longueur et du type de câble utilisé Vérifier la version du logiciel version secteur ou version secteur batterie Vérifier la présence d une source de 20KHz à l entrée de l amplificateur pour obtenir 15V sur la sortie 100V Attention Les amplificateurs Secteur Batterie doivent être calibrés 2 fois en Batterie seul puis en Batterie Sect...

Page 7: ... de tester sa liaison série Débrancher le secteur Débrancher la batterie Positionner les cavaliers A B C D vers l arrière Fig 4 Débrancher V3 Relier Tx à Rx et Tx à Rx L amplificateur se met en autotest RS Si la liaison série RS est bonne le voyant n 7 des lignes HP glignotent B DEPANNAGE Voir tableau ci dessous 5 1 Without any external device Unplug all power source AC and Battery Set the Speaker...

Page 8: ...la borne N 4 du bornier V4 et le point T100 sortie 100V du transfo de sortie La liaison carte de surveillance est défectueuse Saturation Led éteinte état normal led allumée signal de sortie saturé signal sur l entrée de l ampli trop fort tension entre B et M 0 48V DC Ecart 5 voir fig 3 tension entreCet M 38V DC Ecart 5 voir fig 3 Apply 0dB Audio Signal on Input LED INDICATOR NORMAL STATUS FAULT RE...