BEFORE YOU BEGIN:

1. Look at the wall and ceiling above the garage door. (The opener and header bracket

must

be securely fastened to structural

supports.)

2. Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware (not supplied) may

be required.

3. Do you have an access door in addition to the garage door? If not, model E1702M Outside Quick Release Accessory is

required. This accessory allows manual operation of the garage door from outside in case of power failure.

4. Complete the following test to make sure your garage door is balanced and is not sticking or binding:

• Lift the door about halfway. Release the door. If balanced, it should stay in place, supported entirely by its springs.
• Raise and lower the door to see if there is any binding or sticking, 20 kgf is the absolute maximum allowable force to raise or

lower the door in any position. If your door binds, sticks, or is out of balance, call a trained door technician.

DOOR TYPES

A.

Sectional Door with curved track

To suit spring balanced Residential Sectional doors

up to 13.0 m

2

.

1

Electrical Connection

A 240 V General Purpose Outlet (GPO) ie. Power Point must be available in close proximity to the powerhead.

This fitting is not part of the Opener hardware and must be supplied by the consumer.

In the event of a power outage or the unit being disconnected from the power source, the door MUST be operated and

supervised so that it completes a full UP and DOWN cycle with no obstructions in place to ensure that the unit

automatically checks that the safety force settings are correct.

Summary of Contents for Entrylift MT50EVO

Page 1: ...future reference MT50EVO Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THO...

Page 2: ...2014 The Chamberlain Group Inc TM Trademark of The Chamberlain Group Inc Registered Trademark of The Chamberlain Group Inc...

Page 3: ...damp or wet space exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacture...

Page 4: ...ce supported entirely by its springs Raise and lower the door to see if there is any binding or sticking 20 kgf is the absolute maximum allowable force to raise or lower the door in any position If yo...

Page 5: ...3 Curved door arm 4 Hanging bracket 2 5 Rail brackets 3 6 Header bracket 7 Door bracket 8 Hardware bag 9 Rail assembly 10 Manual 11 Warning Labels 12 Rail centre bracket Your garage door opener rail...

Page 6: ...oceed with the assembly installation and adjustment procedures in this manual you may find it helpful to refer back to this illustration of a completed installation COMPLETED INSTALLATION 9 4x 8 8x 7...

Page 7: ...when remote controls are not available Open Stop Close 7 LEDs 1 Remote Control Indicator 2 Program DOWN indicator Door Operating Passpoint indicator 3 Program UP indicator No Function Polarity Comment...

Page 8: ...Rail brackets 4 and the screws 5 This completes the assembly of the door opener to the rail FASTEN RAIL TO OPENER 9 10 The segmented rail is largely preassembled and consists of 3 parts The carriage p...

Page 9: ...al lines created in the previous section for proper placement of header bracket A Wall mount centre the header bracket 1 on the vertical centre line 2 with the bottom edge of the header bracket on the...

Page 10: ...etween door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively par...

Page 11: ...ge is not obstructed The carriage can not pass through the bracket Mounting at the very back fig B is ideal 3 Bend ceiling fixtures 1 in such a way that they lie flat against the ceiling Depending on...

Page 12: ...opener is installed the handle should be no higher then 1 8 metres from the floor The cord may need to be extended Attach the manual release Instruction Label to the cord as indicated in fig 1 DO NOT...

Page 13: ...e force of the motor all LED indicators will stop after this operation LIMITS AND FORCE ARE NOW SET SETTING THE FORCE MANUAL LEARN IF REQUIRED If the limits are already set the force can be set manual...

Page 14: ...erse test When the door reverses off the 40 mm obstacle remove the obstacle and run the opener through a complete travel cycle Door must not reverse in closed position If it does repeat Program the Li...

Page 15: ...e floor Attach bracket assemblies with carriage bolts as shown Adjust right and left side bracket assemblies to the same distance out from mounting surface Make sure all door hardware obstructions are...

Page 16: ...22 1 service www chamber a n de nfo chamber a n de B B A 2 114A3361 For Service Call Installation Date 3 132A2900 RISK OF ENTRAPMENT Repeat Safety Reverse Test monthly Door must reverse on contact wit...

Page 17: ...opener 2 Press and release the S button The LED 1 indicator light will glow steadily 3 Enter a 4 digit personal identification number PIN of your choice on the keypad 4 Press and hold the ENTER button...

Page 18: ...If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary adjus...

Page 19: ...mote control 5 Model E940M 1 Channel visor remote control 6 Model E943M 3 Channel visor remote control 7 Model E945M 3 Channel mini remote control 8 Model E840M Keyless entry system 9 Model C77 The Pr...

Page 20: ...ersons in order to avoid hazard RAIL REPLACEMENT PARTS 041A4017 Motor shaft adapter PVC 041A4021 Trolley latch chain 041A4016 Position tab chain 041A4001EV Logic Board 041A4024 Transformer 041A4033 Mo...

Page 21: ...process and may have dislodged 1 Opener doesn t operate from either door control or remote Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circ...

Page 22: ...3 min Door Linkage Adjustable door arm Pull cord trolley release Safety Personal Push button stop in UP and DOWN direction Automatic safety reverse in both UP and DOWN direction Electronic Automatic...

Page 23: ...aler will provide you with either repairs to the Unit or a replacement Unit Repairs and replacement parts provided under this Chamberlain Limited Warranty are provided free of charge and are warranted...

Page 24: ...TM Trademark of The Chamberlain Group Inc Registered Trademark of The Chamberlain Group Inc Warranty Registration To validate your warranty you must complete the registration form online at gomerlin...

Reviews: