background image

19

learn wireless control button (P2/RADIO)

Press  and  hold  P2/RADIO,  until  the  red  LED  is  lit,  to  begin  learning  wireless  remote 
controls. The red LED will be lit. Press a button for 3 seconds on each wireless control to 
be learned. Either wait 10 seconds, or press P2/RADIO again to exit learning. If the CH-
RADIO jumper is fitted, the wireless controls will operate the pedestrian Access mode; if it 
is removed then they will operate the gate normally.
To enter the Professional Setup routine press P2/RADIO within 5 seconds of pressing 
RESET, or applying power to the board, or while the yellow LED is flashing. 

learn wireless pedestrian access jumper (CH-RADIO) 

Place this jumper over the pins when you want to learn wireless remotes for Pedestrian 
Access mode.

force/speed/voltage setting trimmer (+ FOR -)

NOTE

  Press P1/SET after adjusting the trimmer.

The energy transferred to an obstruction is determined by the motor power, and the time 
that the power is applied to the obstruction. Motor power is determined by the maximum 
voltage and maximum current. This FOR setting alters the motor voltage. The Application 
Mode (page 7) alters the maximum allowable motor current. The OBS setting alters the 
time that power is applied to an obstruction. So safety is determined by a combination of 
the settings for FOR, OBS, and Application Mode.
Turn FOR clockwise to increase the voltage that is applied to the motors.
•  

Full clockwise: maximum voltage (less sensitive)

•  

Full anti-clockwise: min. voltage, approx. 50% of the maximum (more sensitive)

NOTE

  Voltage affects the speed of the motor. After any adjustment to FOR, either the 

Easy Setup or the Professional Setup procedure must be completed to set the operating 
time correctly.

auto-close pause setting trimmer (+ PAU -)

NOTE

  Press P1/SET after adjusting the trimmer.

WARNING

 Photocell sensor beams must be fitted when using auto-close.

This trimmer determines the length of time that the gate pauses before auto-closing.
•  

Full clockwise: auto-closing is disabled (that is, there is an unlimited pause when 
open)

•  

Full anti-clockwise: pause open for 15 seconds, then auto-close (unless a photocell 
is fitted)

•  

Other positions: adjust for pause times of between 3 seconds and 60 seconds

NOTE 

 In  auto-closing  mode,  any  command  to  open  or  close  will  cause  the  following 

behaviour:
•  

while opening, commands are ignored;

•  

while closing, commands will cause the gate to start to open;

•  

while paused open, commands will not close or open, but will restart the pause 
timer

Summary of Contents for G715D

Page 1: ...ase have your serial number and model name available before calling Australia 1800 638 234 New Zealand 0800 653 667 United Kingdom 0800 073 0112 www merlingo com G715D remote control openers security...

Page 2: ...a switch that prevents the drive from operating when the wicket is open Connect a Normally Closed switch to the STP and GND terminals of the controller board Locate controls carefully Install any xed...

Page 3: ...power supply from the drive before cleaning or maintaining the gate or drive The drive or gate may operate unexpectedly due to other users with remote controls or due to automatic closing if enabled B...

Page 4: ...The gate and its moving parts may sustain damage or wear presenting additional load to the opener Frequently examine the installation for signs of wear or damage Do not use if repair or adjustment is...

Page 5: ...D will blink during learning The controller is ready for another wireless control when the red LED is steadily lit 4 Press P2 RADIO to exit learning mode NOTE The learning procedure will time out afte...

Page 6: ...isible exing of the mounting points under load Level and square the gate The gate track should be perfectly level along its full length The gate and its tracks and rollers should not be damaged or ben...

Page 7: ...t waterproof and are only rated for interior use The Merlin KWF1 keyed switch is not intended for use fully exposed to weather in gate installations Merlin does not warranty any items used outside the...

Page 8: ...g that the drive is parallel to the gate Operate the manual release clutch using the key provided pulling the lever fully out Fix the rack to the gate With the clutch released slide the rack over the...

Page 9: ...ads PE beams ensure the total combined load on the VA and TXF terminals does not exceed 150 mA If necessary remove accessories or provide additional power supplies directly to each accessory transform...

Page 10: ...arranged as red to terminal 3 VA grey to terminal 8 EL black to terminal 7 ground The ELU Electric Lock Unit module can accept a lock rated at up to 12V 15W The LCU Lamp Control Unit module can accept...

Page 11: ...en using the Professional Setup routine The gate will close automatically if auto close is enabled otherwise another manual command is required Normal opening and closing commands take priority over P...

Page 12: ...RADIO until the red LED is lit 2 Press P1 SET and observe the number of ashes of the yellow LED 2 ashes are required 3 Press P1 SET again until 2 yellow LED ashes occur 4 Press P2 RADIO to exit progr...

Page 13: ...13...

Page 14: ...G715D May 05 Template for G715D foundation plate M8 8 8 M8 This edge to face the rack gate and pinion...

Page 15: ...cable entry hole NOTE Ensure cables and conduit are pulled through the cable entry holes when the plate is bolted to the ground 8 8 M8 M8 cable entry hole...

Page 16: ...G715D May 05 16...

Page 17: ...D is ashing press P1 SET again for 1 second The following steps are performed automatically 1 Checks for presence of a motor photocells or a jumper on PHO terminal e stop or a jumper on STP terminal 2...

Page 18: ...LED stops ashing Press within 5 seconds of applying power to the board or while the yellow LED is ashing to enter the Easy Setup routine Also used in conjunction with P2 RADIO to set the Application M...

Page 19: ...mum allowable motor current The OBS setting alters the time that power is applied to an obstruction So safety is determined by a combination of the settings for FOR OBS and Application Mode Turn FOR c...

Page 20: ...ec after the interruption is removed the gate will close Gate closing stop if the beam is interrupted then open fully when the beam is clear pause for 1 second and begin to close PAU in all other posi...

Page 21: ...one button for P2 learn the button with the CH RADIO jumper tted The following steps are performed automatically 1 Checks for presence of a motor photocells or a jumper on PHO terminal e stop or a ju...

Page 22: ...12 If Pedestrian Access is not required press P1 SET and P2 RADIO simultaneously NOTE The professional setup procedure will time out after four minutes if abandoned Testing the gate operation Test the...

Page 23: ...ing to which the Unit is attached G Faulty or at batteries in the remote control transmitter H Where the defect is due to conditions other than normal domestic use or dirt misuse neglect re accident e...

Page 24: ...iced if it is heavy to move by hand Transmitter range is less than normal Your transmitter battery may be going at If you have an external antenna then the wire may be damaged SOLUTION Replace the tra...

Page 25: ...max 40 W per motor Gate weight max 500 kg Operating speed typ 10 m min Replacement board fuse 2 A 5 x 20 Replacement motor fuse 10 A 5 x 20 Remote control battery Depends on model either 4LR44 6V or C...

Page 26: ...es or phone Merlin toll free New Zealand Auckland phone 09 415 4393 Phone toll free 0800 653 667 or 0800 MERLIN Fax toll free 0800 653 663 Australia NSW Vic Qld WA Phone toll free 1 800 638 234 Fax to...

Page 27: ...ose quick close after photocell OBS obstruction sensing delay 0 1 to 2 5 sec 0 1 sec delay 2 5 sec delay TEST delay all 0 2 sec RESET red P2 RADIO P1 SET P1 SET P2 RADIO red yellow yellow P2 RADIO P2...

Page 28: ...e speed voltage 50 100 cw max TEST jumper ON OFF Gates New or existing Leaf width x height Construction type coverage Load measured at gate bracket without opener connected Contact details Signed by i...

Reviews: