obstruction is removed

10.  

The gate will close fully, slowing down at the time previously chosen

Only perform step 11 if pedestrian access is required:
11.  

Press P1/SET or P2/RADIO. The gate will begin opening. Press P1/SET at the 
time where the gate is at the desired open position for pedestrian access. The gate 
will close fully and the unit will exit Professional Setup.

12.  

If  Pedestrian  Access  is  not  required,  press  P1/SET  and  P2/RADIO 
simultaneously

NOTE

 The professional setup procedure will time out after four minutes if abandoned.

Testing the gate operation

Test the operation of all controls and safety devices.
Allow for the effect of weather. Wind or water may make the gates more difficult to move.
If the sensitivity is set to react to extremely light obstructions then the gates may fail to 
open or close fully. 
After adjustment, check that the force on an obstruction at the far end of the gate leaf 
does not exceed 150N (15 kg). Use a spring balance.

Summary of Contents for G715D

Page 1: ...ase have your serial number and model name available before calling Australia 1800 638 234 New Zealand 0800 653 667 United Kingdom 0800 073 0112 www merlingo com G715D remote control openers security...

Page 2: ...a switch that prevents the drive from operating when the wicket is open Connect a Normally Closed switch to the STP and GND terminals of the controller board Locate controls carefully Install any xed...

Page 3: ...power supply from the drive before cleaning or maintaining the gate or drive The drive or gate may operate unexpectedly due to other users with remote controls or due to automatic closing if enabled B...

Page 4: ...The gate and its moving parts may sustain damage or wear presenting additional load to the opener Frequently examine the installation for signs of wear or damage Do not use if repair or adjustment is...

Page 5: ...D will blink during learning The controller is ready for another wireless control when the red LED is steadily lit 4 Press P2 RADIO to exit learning mode NOTE The learning procedure will time out afte...

Page 6: ...isible exing of the mounting points under load Level and square the gate The gate track should be perfectly level along its full length The gate and its tracks and rollers should not be damaged or ben...

Page 7: ...t waterproof and are only rated for interior use The Merlin KWF1 keyed switch is not intended for use fully exposed to weather in gate installations Merlin does not warranty any items used outside the...

Page 8: ...g that the drive is parallel to the gate Operate the manual release clutch using the key provided pulling the lever fully out Fix the rack to the gate With the clutch released slide the rack over the...

Page 9: ...ads PE beams ensure the total combined load on the VA and TXF terminals does not exceed 150 mA If necessary remove accessories or provide additional power supplies directly to each accessory transform...

Page 10: ...arranged as red to terminal 3 VA grey to terminal 8 EL black to terminal 7 ground The ELU Electric Lock Unit module can accept a lock rated at up to 12V 15W The LCU Lamp Control Unit module can accept...

Page 11: ...en using the Professional Setup routine The gate will close automatically if auto close is enabled otherwise another manual command is required Normal opening and closing commands take priority over P...

Page 12: ...RADIO until the red LED is lit 2 Press P1 SET and observe the number of ashes of the yellow LED 2 ashes are required 3 Press P1 SET again until 2 yellow LED ashes occur 4 Press P2 RADIO to exit progr...

Page 13: ...13...

Page 14: ...G715D May 05 Template for G715D foundation plate M8 8 8 M8 This edge to face the rack gate and pinion...

Page 15: ...cable entry hole NOTE Ensure cables and conduit are pulled through the cable entry holes when the plate is bolted to the ground 8 8 M8 M8 cable entry hole...

Page 16: ...G715D May 05 16...

Page 17: ...D is ashing press P1 SET again for 1 second The following steps are performed automatically 1 Checks for presence of a motor photocells or a jumper on PHO terminal e stop or a jumper on STP terminal 2...

Page 18: ...LED stops ashing Press within 5 seconds of applying power to the board or while the yellow LED is ashing to enter the Easy Setup routine Also used in conjunction with P2 RADIO to set the Application M...

Page 19: ...mum allowable motor current The OBS setting alters the time that power is applied to an obstruction So safety is determined by a combination of the settings for FOR OBS and Application Mode Turn FOR c...

Page 20: ...ec after the interruption is removed the gate will close Gate closing stop if the beam is interrupted then open fully when the beam is clear pause for 1 second and begin to close PAU in all other posi...

Page 21: ...one button for P2 learn the button with the CH RADIO jumper tted The following steps are performed automatically 1 Checks for presence of a motor photocells or a jumper on PHO terminal e stop or a ju...

Page 22: ...12 If Pedestrian Access is not required press P1 SET and P2 RADIO simultaneously NOTE The professional setup procedure will time out after four minutes if abandoned Testing the gate operation Test the...

Page 23: ...ing to which the Unit is attached G Faulty or at batteries in the remote control transmitter H Where the defect is due to conditions other than normal domestic use or dirt misuse neglect re accident e...

Page 24: ...iced if it is heavy to move by hand Transmitter range is less than normal Your transmitter battery may be going at If you have an external antenna then the wire may be damaged SOLUTION Replace the tra...

Page 25: ...max 40 W per motor Gate weight max 500 kg Operating speed typ 10 m min Replacement board fuse 2 A 5 x 20 Replacement motor fuse 10 A 5 x 20 Remote control battery Depends on model either 4LR44 6V or C...

Page 26: ...es or phone Merlin toll free New Zealand Auckland phone 09 415 4393 Phone toll free 0800 653 667 or 0800 MERLIN Fax toll free 0800 653 663 Australia NSW Vic Qld WA Phone toll free 1 800 638 234 Fax to...

Page 27: ...ose quick close after photocell OBS obstruction sensing delay 0 1 to 2 5 sec 0 1 sec delay 2 5 sec delay TEST delay all 0 2 sec RESET red P2 RADIO P1 SET P1 SET P2 RADIO red yellow yellow P2 RADIO P2...

Page 28: ...e speed voltage 50 100 cw max TEST jumper ON OFF Gates New or existing Leaf width x height Construction type coverage Load measured at gate bracket without opener connected Contact details Signed by i...

Reviews: