background image

22

DIAGNOSTIC CHART

30

Your garage door opener is programmed with self-diagnostic capabilities. The indicator LEDʼs 1 & 3 on the control panel will flash a 

number of times to indicate a fault code exists.

DIAGNOSTIC CODE
LED1        LED2

SYMPTOM

POSSIBLE RESOLUTION

1

1

The garage door opener will not 

close and the courtesy light 

flashes.

The Protector System

TM

 (IR beams) are open circuit or wires may be 

cut. Inspect sensor wires for a disconnected or cut wire. Turn power off 

and reboot the opener.

1

2

The garage door opener will not 

close and the courtesy light 

flashes.

There is a short circuit wire for the The Protector System

TM

 (IR beams). 

Inspect The Protector System

TM

 (IR beams) wire at all staple points and 

replace wire or correct as needed. Turn power off and reboot the 

opener.

1

3

The door control will not 

function.

The wires for the door control are shorted or the door control is faulty. 

Inspect the wire at all staple points and connection points and replace 

wire or correct as needed.

1

4

The garage door opener will not 

close and the courtesy light 

flashes.

The Protector System

TM

 (IR Beams) are misaligned or were momentarily 

obstructed. Realign both sensors to ensure both LEDs are steady and 

not flickering. Make sure nothing is hanging or mounted on the door that 

would interrupt the sensors path while closing.

1

5

There is no door movement or 

motor accelerates before 

stopping suddenly.

No RPM pulses have been detected. Check the door manually for 

balance, binding or obstructions. Internally the possible cause may be 

the motor, logic board or RPM sensor. Try resetting door travel limits. 

Contact service centre.

2

1

Opener fails to operate.

Possible PCB memory failure. Reboot opener by turning the mains 

power OFF and then ON after 15 seconds. Reprogram the door travel 

limits and force settings. Contact service centre.

2

2

Opener fails to operate.

Possible PCB Voltage failure. Reboot opener by turning the mains 

power OFF and then ON after 15 seconds. Reprogram the door travel 

limits and force settings. Contact service centre.

2

4

Opener fails to operate using 

the transmitters

Possible receiver failure. Reboot opener by turning the mains power 

OFF and then ON after 15 seconds. Recode the transmitters. Contact 

service centre.

4

1

Door is moving down, stops 

and reverses.

Manually open and close the door. Check for binding or obstructions, 

such as a broken spring or door lock. If the door is binding or sticking 

contact a trained door systems technician. If door is not binding or 

sticking, reset the limits (refer to “Program the Travel Limits and Force” 

section).

4

2

Door is moving up, stops and 

reverses.

Manually open and close the door. Check for binding or obstructions, 

such as a broken spring or door lock. If the door is binding or sticking 

contact a trained door systems technician. If door is not binding or 

sticking, reset the limits (refer to “Program the Travel Limits and Force” 

section).

OPERATION AND MAINTENANCE

TM

 Trademark of The Chamberlain Group LLC 

®   Registered Trademark of The Chamberlain Group LLC
©  2022 The Chamberlain Group LLC

Summary of Contents for Merlin WeatherDrive MR555MYQ

Page 1: ...rmation DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY MR555MYQ Garage Roller Door Opener Installation and Operating Instructions Owners Copy SAVE THESE INSTRUCTIONS for future referen...

Page 2: ...AVAILABLE when using the Key Lockable Feature This Merlin Unit is rated to IP34 and has a UV stabilizer added however to ensure the best operation of the opener the installer must ensure that it is pr...

Page 3: ...f water from all practicable Protection against low pressure practicable directions strong jet of water from all Protection against heavy seas or a immersion Protection against temporary than second n...

Page 4: ...h the proper operation of the safety reverse system or damage the garage door Installers must ensure that the doors are installed in a compliant manner as per AS NZS 60335 2 95 After installation ensu...

Page 5: ...m extended socket and socket wrench 4 300 mm socket extension for minimum side room installations 5 Drill and 5 5 mm drill bit 6 Philips head screwdriver 7 Marker pen 8 Rope 9 Door stand not shown DOO...

Page 6: ...Lock used to lock the engage disengage mechanisim for commercial applications 7 LEDs 1 Program DOWN and Diagnostic code indicator Number 1 2 Program UP indicator 3 Diagnostic code indicator Number 2...

Page 7: ...be installed on the opposite side of the door to where the opener is to be installed Ensure the U Bolt holding the door shaft to the door bracket is tightly secure NOTE This U Bolt must not be remove...

Page 8: ...ining the correct fastener location as shown lift the door approximately half a turn from the closed position to allow access for securing the screws The manual release mechanism enables the door to b...

Page 9: ...fety standard AS NZS 60335 2 95 An alternative exit path from the building MUST BE AVAILABLE when using the Key Lockable Feature Lock or unlock as required Insert key into Release Handle 8 mm allen ke...

Page 10: ...y support the door Mark the position of the door shaft on the right hand door bracket for reassembly purposes While the door is supported remove the right hand axle U Bolt and door mounting bracket fr...

Page 11: ...the door guides 5 Press and release the P program button to accept this setting 6 Press and hold the DN button until the door reaches the desired CLOSED position You can toggle between the UP and DN...

Page 12: ...or must reverse on contact with a 40mm obstacle placed on the floor Make necessary adjustments AUTOMATIC DRIVE Keep away from the area of the door since it may operate unexpectedly EMERGENCY RELEASE T...

Page 13: ...Timer to Close A BEEP will register for each press DN button will reduce the count if needed Press and release the P button to accept this setting To deactivate the Timer to Close Start with the door...

Page 14: ...he door fully OPEN Press and Hold both UP and DN buttons for 3 seconds The Courtesy light will flash TWICE Release both Buttons The WeatherDrive MR555MYQ has been factory set with the Control Panel bu...

Page 15: ...ilation activation mode by pressing the P and UP buttons together for 3 seconds figure 2 Release when the courtesy light flashes once 3 Press the transmitter button that you have allocated for this fe...

Page 16: ...ding for approximately 8 seconds until the courtesy light flashes twice again 2 Release the button all codes are now erased Activate the opener only when door is in full view free of obstruction and p...

Page 17: ...if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious injury could result CARE OF YOUR OPENER MAINTENANCE OR YOUR OPENER When properly installed your o...

Page 18: ...placed inside any part of the body call the 24 hour Poisons Information Centre on 13 11 26 in Australia or the 24 hour National Poisons Centre on 0800 764 766 in New Zealand or seek immediate medical...

Page 19: ...or are the springs broken Remove the obstruction or repair the door 7 Door reverses for no apparent reason and opener lights flash 10 times Check The Protector SystemTM IR Beams if you have installed...

Page 20: ...M 4 Channel remote control 4 Model E964M 4 Channel remote control 5 Model E138M 2 Channle Wireless wall button 6 Model E960M 4 Channel remote control 7 Model E940M 1 Channel visor remote control 8 Mod...

Page 21: ...65 002A1869 002A1874 002A1872 002A1864 002A1873 002A1871 Motor with gearbox clutch Sungear kit PCB assembly Transformer Clamp assembly Handle pull rope assembly Absolute Position Encoder APE Weight Ba...

Page 22: ...ected Check the door manually for balance binding or obstructions Internally the possible cause may be the motor logic board or RPM sensor Try resetting door travel limits Contact service centre 2 1 O...

Page 23: ...lete the registration form online at gomerlin com au warranty or gomerlin co nz warranty Get Connected with Visit www gomerlin com au or www gomerlin co nz for more details Additional purchase of the...

Page 24: ...d free of charge and are warranted for the remaining portion of the original warranty period This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and remedies...

Reviews: