20
PROGRAMMING
INITIAL SETUP
20
S
P
+
-
ARTICULATED ARM
SINGLE
S
P
+
-
S
P
+
-
MAIN MENU
DIRECTION MOTOR1
PRESS & HOLD “+”
GATE OPENING?
YES “P”, NO “S”
S
P
+
-
MAIN MENU
DIRECTION MOTOR1
S
P
+
-
MAIN MENU
SELECT
APPLCATION
S
P
+
-
CYCLES: 000, 000
BEGIN SETUP
S
P
+
-
MAIN MENU
SELECT
APPLCATION
S
P
+
-
MAIN MENU
SELECT
APPLCATION
S
P
+
-
MAIN MENU
LIMITED & FORCE
LEARN
S
P
+
-
MAIN MENU
SELECT
APPLCATION
S
P
+
-
MAIN MENU
LIMITED & FORCE
LEARN
S
P
+
-
CYCLES 000,000
STANDBY
GATE CLOSED
Energise the opener. Release the opener manual release
with the key, and move the gate(s) to a mid open position.
Re-engage the manual release.
The LCD screen will display the Cycle count.
1. Press and hold the “P” button for approximately 5
seconds to enter into the Main Menu. MAIN MENU
SELECT APPLICATION will be displayed on the LCD.
2. Press the “P” button once to enter this Menu option.
3. Use the “+” or “-” to scroll though the motor application
options. When “ARTICULATED ARM SINGLE OR
ARTICULATED ARM DUAL” is shown, press the “P”
button to select. The screen will change to show MAIN
MENU SELECT APPLICATION.
4. Press the “+” button once to scroll to the next menu
option. “MAIN MENU DIRECTION MOTOR1” will be
displayed on the LCD.
5. Press the “P” button to select. The screen will change
to show PRESS & HOLD “+” GATE OPENING? YES
“P”, NO “S”.
6. Press and hold “+”. The gate will start to move.
a) If it moves in the OPEN direction, press “P” to
confirm”. The screen will change to show MAIN
MENU DIRECTION MOTOR!
b) If the gate moves in the CLOSE direction, press
“S” to confirm. The screen will change to
EXECUTE MOTOR DIRECTION CHANGE.
Press “P” to confirm.
Once the direction has been confirmed, the
screen will change to MAIN MENU DIRECTION
MOTOR. If there is a second slide gate opener to
be setup, press the ”+” button to scroll to the
next menu option “MAIN MENU DIRECTION
MOTOR2 and follow the steps 5 and 6.
7. Press the “+” button once to scroll to the next menu
option. “MAIN MENU LIMIT&FORCE LEARN” will be
displayed on the LCD.
8. Press the “P” button to select.
The gate will start to
move.
The screen will change and LIMIT&FORCE
LEARN will flash on the screen.
9. Once complete, the gate will stop moving and the
screen will change to CYCLES: 000,000 STANDBY
GATE CLOSED.
Initial setup is now complete. The opener will now operate
using default Basic Settings.
NOTE: If the LIMIT&FORCE LEARN setup needs to be
stopped, press the “S” button. The Screen will display
LIMIT&FORCE LEARN INTERRUPTED. After 5
seconds, the screen will display LIMIT&FORCE
LEARN. Repeat step 8 to complete basic setup.