35
OPERATION AND MAINTENANCE
ERROR CODES
46
Error
Problem
Action Required
How to Clear
ERR:
MOTOR1
ERR:
MOTOR1
•
PCB has detected a
motor failure
•
Power down the gate operator for 20 seconds.
•
Once the gate has been powered up again,
check if the PCB has reset. If not, change the
PCB.
•
Power down for 20
seconds and power on
to reset.
ERR: PCB
•
PCB memory failure
•
Power down the gate operator for 20 seconds.
•
Once the gate has been powered up again,
check if the PCB has reset. If not, change the
PCB.
•
Power down for 20
seconds and power on
to reset.
ERR: OBSTR.
MOT1
ERR: OBSTR.
MOT2
•
Motor # is blocked and
unable to move
•
Check the motor is free to move.
•
Clear any obstruction.
•
Check any pivot points or track for debris
jamming the motor or gate.
•
Auto reset once the issue
has been resolved. (may
take up to 16 seconds)
ERR:
MOTOR1
RPM
ERR:
MOTOR2
RPM
•
Motor # is stalled or
RPM is damaged
•
Check if the motor is stalled or RPM is damaged
•
Auto reset once the issue
has been resolved. (may
take up to 16 seconds)
ERR: RADIO
•
Radio module failure
•
Power down the gate operator for 20 seconds.
•
Once the gate has been powered up again,
check if the PCB has reset. If not, change the
PCB.
•
Power down for 20
seconds and power on
to reset.
ERR:
BATTERY
•
Battery Voltage is low
•
Check the battery voltage
•
Charge battery
•
Auto reset once the issue
has been resolved. (may
take up to 16 seconds)
ERR: SYNC
•
SYNC connector is
short circuited
•
Check if the SYNC connector is short circuited.
•
Auto reset once the issue
has been resolved. (may
take up to 16 seconds)
ERR: LIMITS
•
Incorrectly pressing ‘C’
during limit learning
•
Relearn limits
•
Reset basic Settings
•
Relearn limits
•
Complete Basic Settings
if required.
Summary of Contents for MGLDK