background image

PowerGuard 

PRO

 

User & Installation Guide Rev A

 

Page 17 

 

Warranty 

 
PowerGuard 

PRO

 is warranted to be free of defects caused during manufacture for a period of 2 years 

from purchase. The warranty may be invalidated if the device has been altered, misused, installed 

incorrectly or operated in adverse conditions described in the “Precautions”

 section of this document. 

 

What does this warranty cover and how long does it last? 

This Limited Warranty is provided by Merlin 

Equipment Limited. (“Merlin”) and covers defects in workmanship and materials in your 

PowerGuard 

PRO

. This warranty period lasts for 24 months from the date of purchase at the point of sale to you, the 

original end user customer, unless otherwise agreed in writing (the “Warranty Period”). You will be 

required to demonstrate proof of purchase to make warranty claims. 
 
This Limited Warranty is transferable to subsequent owners but only for the unexpired portion of the 

Warranty Period. Subsequent owners also require original proof of purchase as described in “What 
proof of purchase is required?”

 

 
What  will  Merlin  do? 

During  the  Warranty  Period  Merlin  will,  at  its  option,  repair  the  product  (if 

economically feasible) or replace the defective product free of charge, provided that you notify Merlin 
of  the  product  defect  within  the  Warranty  Period,  and  provided  that  Merlin  through  inspection 
establishes the existence of such a defect and that it is covered by this Limited Warranty. 
 
Merlin  will,  at  its  option,  use  new  and/or  reconditioned  parts  in  performing  warranty  repair  and 
building  replacement  products.  Merlin  reserves  the  right  to  use  parts  or  products  of  original  or 
improved design in the repair or replacement. If Merlin repairs or replaces a product, its warranty 
continues for the remaining portion of the original Warranty 
Period or 90 days from the  date of the return shipment to the  customer, whichever is greater. All 
replaced products and all parts removed from repaired products become the property of Merlin. 
 
Merlin  covers  both  parts  and  labour  necessary  to  repair  the  product,  and  return  shipment  to  the 
customer via a Merlin-selected non-expedited surface freight within the contiguous United States and 
Canada. Alaska, Hawaii and outside of the United States and Canada are excluded. In Europe, this is 
the EMEA. Contact Merlin Customer Service for details on freight policy for return  shipments from 
excluded areas. 
 

How do you get service? 

If your product requires troubleshooting or warranty service, contact your 

merchant. If you are unable to contact your merchant, or the merchant is unable to provide service, 
contact  Merlin  directly  at:  Merlin  Equipment  Ltd,  Unit  4,  Cabot  Business  Village,  Poole  BH17  7BA, 
United Kingdom. Tel: +44 (0) 1202 697979.

 

 
 

 

Summary of Contents for PowerGuard PRO

Page 1: ...m User Installation Guide Revision A Merlin Equipment Ltd Clyst Court Hill Barton Industrial Estate Exeter Devon EX5 1SA United Kingdom T 44 0 1202 697979 Merlin Power Systems 332 4 West Montauk Highway Hampton Bays New York NY11946 United States of America T 1 631 594 5102 www merlinequipment com ...

Page 2: ...uard PRO is designed for installation by qualified and competent electrical engineers Qualified and competent engineers will be familiar with safe working practices local health safety legislation and the proper and safe use of tools and equipment Therefore not all obvious practices that may lead to system damage injury or death are detailed within this manual If you are in anyway unsure about any...

Page 3: ...lectric shock damage or other injury FUSES Use the correct ampere rating when replacing fuses Failure to do so may result in fire injury electric shock or damage DO NOT install or operate the CPU in an explosive atmosphere DO NOT install or expose the CPU to excessive temperatures or humidity If in any doubt consult a suitably qualified and competent engineer or the supplier DO NOT substitute Cont...

Page 4: ...s of EU Electromagnetic Compatibility EMC Directive 2014 30 EU PowerGuard PRO complies with RoHS Reduction of Hazardous Substances Directive 2011 65 EC At the end of life PowerGuard Pro should be disposed of as normal electrical waste PowerGuard PRO has been tested to and surpasses ISO 7637 2 for use on vehicles Signed James Hortop Managing Director Merlin Power Systems UK Date 18th January 2019 V...

Page 5: ...nition is switched on PowerGuardPRO may be used on 1 or 2 battery bank installations at either 12 or 24VDC Those battery banks may also be of mixed voltage e g a 12 and a 24V battery bank Please take the time to read and understand this manual before installation and use Please note that this manual refers to the PowerGuardPRO retail product PowerGuardPRO is available in an OEM version The OEM ver...

Page 6: ...or Switch x1 Flat Battery Protection Reset Switch x1 Fuse Kit Rubber Blanking Plugs Installation Manual this document Twin Battery Models 04 8103 12V and 04 8104 24V PowerGuard PRO CPU x1 PowerGuard PRO Contactor x2 Part Numbers SU80 5164MPL 12V or Part Numbers SU80 5165 24V Remote Battery Isolator Switch x2 Flat Battery Protection Reset Switch x1 Fuse Kit Rubber Blanking Plugs Installation Manual...

Page 7: ...gine room bulkhead or a cupboard It is suitable for installation in drier engine compartments on boats However it is not sealed against moisture ingress The CPU is NOT suitable for installation or operation in atmospheres where there is a risk of ignition or explosion Contactors These are designed to be installed under hood in wet engine room environments and battery compartments The contactors ar...

Page 8: ...on Guide Rev A Page 8 Wiring Layouts These wiring layouts cover the majority of installations Typical Single Battery System Figure 1 Single battery wiring schematic Typical Twin Battery System Figure 2 Twin battery wiring schematic ...

Page 9: ...serve correct polarity of Contactor wiring will result in incorrect operation of the system and may cause serious damage Serious damage to the PowerGuardPRO will occur if the wires to the Contactor coils are incorrectly connected or short circuited Contactor Rating Contactors are rated for charging systems of up to 200A Continuously They will also handle intermittent cranking current of engines up...

Page 10: ...Remote Battery Switching The Battery Isolator switches control connection or disconnection of the battery or batteries PowerGuard PRO can switch up to 2 independent battery banks Flat Battery Protection PowerGuardPRO can prevent a flat battery condition by disconnecting the battery or batteries from the load It achieves this by monitoring the battery voltage levels If the voltage level falls below...

Page 11: ...rrectly Caution Warning Do NOT overtighten However failure to tighten the stud nuts adequately may result in an intermittent connection and or arcing which may cause overheating or ignition CPU Caution Damage will occur if the CPU is allowed to get wet Warning Do not install the CPU in a petrol gas engine room environment The CPU is designed for location in a dry environment such as on cab side of...

Page 12: ...h temperature thin wall low voltage cable suitable for use in automotive marine and allied industries By Pass Loads There may be certain loads attached to the battery that should not be subject to Flat Battery Protection disconnection For example some engine management computers hazard warning lights etc In some states countries these this may be mandated by law Bypass loads should be identified i...

Page 13: ...t voltage for battery 1 Single battery system B2 VOLTS Sets the internal threshold disconnect voltage for battery 2 Twin battery system TIME DELAY Adjusts the functional time delay the delay prevents relay chatter The range of controls is B1 PowerGuard 1 voltage threshold range 10 5 to 12 7 V DC 21 0 to 25 4 V DC for 24V unit B2 PowerGuard 2 voltage threshold range 10 5 to 12 7 V DC 21 0 to 25 4 V...

Page 14: ...o provide advice if required While the trim pots may be adjusted while PowerGuardPRO is powered up we recommend removing the B1 and B2 sense fuses to prevent accidental shorting of components on the PCB and potential PowerGuard PRO damage Adjustments to trim pot settings should be carried out using an insulated trimming tool A small 1 5mm flat blade screwdriver can be used but extra care is requir...

Page 15: ...he ignition is switched on you MUST NOT release the vehicle boat into service Severe damage and potentially hazardous situations may occur if B1 is disconnected when the engine is running 4 Turn the ignition off Note the voltage of B1 Apply loads to B1 When the voltage drops below the pre set disconnect voltage for a period exceeding the pre set Time Delay you should hear the B1 Contactor disconne...

Page 16: ...PowerGuard PRO User Installation Guide Rev A Page 16 Product Specifications ...

Page 17: ... product defect within the Warranty Period and provided that Merlin through inspection establishes the existence of such a defect and that it is covered by this Limited Warranty Merlin will at its option use new and or reconditioned parts in performing warranty repair and building replacement products Merlin reserves the right to use parts or products of original or improved design in the repair o...

Page 18: ... Installation Guide Rev A Page 18 REVISION PAGE NOT FOR PUBLICATION Rev1 3 Correcting E number Page4 V1 2 erroneously showed SmartBank Pro E number Rev1 3 Track changes set Rev A Updates to standards and general revisions ...

Reviews: