OPERATION OF YOUR OPENER
Your opener can be activated by any of the following
devices:
• Opener Control Panel: UP & DOWN buttons, and
O.S.C. control button.
• Transmitter: hold the button down until the door
starts to move.
• Wireless Entry Keypad: This is an accessory that
opens the door using a four digit keycode.
When the opener is activated:
• If open, the door will close. If closed, the door will
open.
• If closing, the door will stop.
• If opening, the door will stop (allowing space for
entry and exit of pets and for ventilation).
• If the door has been stopped in a partially open or
closed position, it will reverse direction.
Obstruction behaviour:
• If an obstruction is encountered while closing, the
door will reverse to the fully open position.
• If an obstruction is encountered while opening, the
door will stop and briefly reverse.
• The Protector System
TM
(IR Beams) use an
invisible beam which, when broken by an
obstruction, causes a closing door to open and
prevents an open door from closing. It is
STRONGLY RECOMMENDED for homeowners
with young children or pets.
Opening the door manually:
The door can be opened manually by pulling the
release cord down firmly.
To re-engage the door, pull the release cord down
firmly.
The opener lights will turn on under the following
conditions:
when the opener is initially plugged in; when power
is restored after interruption or when the opener is
activated.The opener light will turn on for 3
minutes when the opener is activated.
MAINTENANCE OF YOUR OPENER
Once a Month:
• Repeat the safety reverse test (see Section 15).
Make any necessary adjustments.
• Manually operate the door. If it is unbalanced or
binding, call for professional garage door service.
• Check to be sure that the door opens and closes
fully.
Set the limits and/or force if necessary.
SPECIAL NOTE: Merlin strongly recommends that
The Protector System
TM
(IR Beams)
be installed on all garage
door openers.
CARE OF YOUR OPENER
When properly installed, your opener will operate with
minimal maintenance. The opener does not require
additional lubrication.
Limit and Force Settings: These settings must be
checked and properly set when the opener is installed.
Weather conditions may cause some minor changes in
the door operation, requiring some re-adjustments,
particularly during the first year of operation. Refer to
limit and force setting in Section 14.
Follow the instructions carefully and repeat the
safety reverse test after any adjustment.
Transmitter: Additional transmitters can be purchased
at any time. Refer to gomerlin.com.au or
gomerlin.co.nz for compatible transmitters. Any new
transmitters must be programmed into the opener.
Transmitter battery: If the transmission range
decreases, replace the battery.
SPECIFICATIONS SILENTDRIVE ELITE
(MR855MYQ)
Input Voltage:
220-240 VAC, 50-60 Hz, 140 W
Rated Load:
35 Nm
Max.Pull Force:
550 N @ O300 mm
Max. door weight:
120 kg
Max lift under Spring Tension: 20 kg
Max. door area:
18 m
2
Drive:
DC gear motor permanent
lubrication
Max. Drum Rotations:
4
1/2
Memory Registers:
64
Operating Frequency:
433.30/433.92/434.54 MHz
Operating Temperature:
55
0
C to -25
0
C
When releasing the door, the door should
be fully closed if possible. Weak or
broken springs could allow an open door
to fall rapidly. Property damage or
serious injury could result.
13