Merloni Elettrodomestici
55 CM WIDE BUILT-IN FRIDGE-FREEZERS
Technical Manual
I
04-10-22/01
13-33
Language
Issue/Edition
Page
6. FZ Evaporator Fan (No-Frost only)
INFORMATION:
How It Works
: it is always switched off with the appliance OFF and can be switched
on when the appliance is in the ON condition only if the compressor is switched on.
Delay in switching on: the fan has a start time delay of about two minutes compared
with that of the compressor and is activated only after the evaporator has cooled to be-
low -18 °C in the first cycle after a defrosting.
POSSIBLE CAUSE OF MALFUNCTION:
Microcontroller management
FZ evaporator fan driver circuit on the board
Connection on the board
Wiring
Connection on the FZ evaporator fan
FZ evaporator fan
TESTING:
General on the appliance
: Carry out the check using the Autotest procedure.
Wiring:
check for continuity and short circuits; check the connections (connectors and
terminals); check for presence of voltage. check that the thermo fuse is not open.
Component
: check with simulated load (lamp); direct check of the fan (powered directly).
Board
: visual check and quick check of the board (blowouts or burnouts, etc.); check by
using a replacement.