Merloni Elettrodomestici
55 CM WIDE BUILT-IN FRIDGE-FREEZERS
Technical Manual
I
04-10-22/01
7-33
Language
Issue/Edition
Page
5
ANALYSIS OF LOADS
1. Compressor
Information
How It Works
: they are managed by the microcontroller based on the temperatures
measured by the probes.
Protection time
: (about eight minutes) the compressor is forced not to switch itself on
before this period of time has elapsed from the last time it was switched off.
Black Out
: the compressor starts running again immediately.
On/Off (on display)
: observes the compressor's 8 minute delayed start.
Possible cause of malfunction
Microcontroller management
Compressor driver circuit on the board
Connection on the board
Wiring
Connection on the compressor
Internal compressor breakdown/fault
TESTING:
General on the appliance
: force the compressor to switch on by activating the
24h SUPER FREEZE function and check that the compressor switches on. Remember
the 8 minutes of compressor protection.
Wiring:
check for continuity and short circuits; check the connections (connectors and
terminals); check for presence of voltage.
Component
: check with simulated load (lamp); direct check of the compressor (pow-
ered directly).
Electronic board
: visual check and quick check of the board (blowouts or burnouts,
etc.); check by using a replacement.