1. Position the wall profile
LR8387C
so the seal on the moving panel
A
sits on the inside edge of the bath.Fig 2
2.
INSTALLATION
Plumb the wall profiles
LR8387C
using the vertical element of the spirit level. Mark 3 holes, drill with 6mm masonry
bit and fit wall plugs
2SP12
. Using the 3 Screw
2SY51
, fix wall profiles to wall. Fig 3.
NOTE: Only silicone the wall profile after fixing to the wall (see sealing section).
Do not silicone on the back of the wall profile before fixing to the wall.
FIG 2
3.
4.
Insert Fixed panel
B
into the wall profile (do not fix it to the wall profile).
Remove the top bracket
BSYS021
by loosening the screw.Insert moving panel
B
and reattach the top hinge bracket. Fig 3.
5. Ensure the bottom seal on the moving panel
A
is parallel to the top surface of the bath. Drill 3 holes through the wall profile
and fixed panel using a 3mm steel drill bit. Using the Screws
2SY50
and cover caps
2SS008
and clips
2SS009
, fix the hinge
upright to the wall profile in 3 places.Fig 4.
screen
inside
bath edge
FIG 3
Inside
Ensure the deflector on the seal is positioned on the inside. Make a cut on one of the bottom corners of the seal to ensure
a correct fit against the hinge bracket – see circled area in. Fig 5
FIG 5
6.
Inside
FIG 4
Outside