MeshLinx MWI-5000 User Guide
MESHLINX CONFIDENTIAL
2
|MX (Mexico)|AT (Austria)|BE (Belgium)|HK (Hong Kong)
|NZ (New England)|TW (Taiwan)|GB (UK)|DE (Germany)|IE (Ireland)
|IT (Italy)|NL (Netherlands)|PT (Portugal)|DK (Denmark)
|FI (Finland)|NO (Norway)|SE (Sweden)|SG (Singapore)|CH (Switzerland)]
[I(Indoor) O(Outdoor) otherwise (Indoor/Outdoor)]
System has to be power reset after changing country code.
Examples:
set ap country CH
-
set China Indoor/Outdoor
set ap country USI
-
set US Indoor
set ap country GBO
-
set UK Outdoor
get ap country
–
displays the selected country code
4.2.3.26
Spectrum Management
set wif<1|2|3|*> specmgmt <enable | disable>
–
make
spectrum
management enable or disable
on a per-wif basis
set wif<1|2|3> chansw <channel> <count>
- causes a wif to switch
channels and the count is the number of
T
arget
B
eacon
T
ransmission
T
imes until the channel switch is to take place.
set wif<1|2|3> quiet <count> <duration>
-
causes a wif to stop
transmitting, including beacons and count is the number of
T
arget
B
eacon
T
ransmission
T
imes until the quiet interval is to take
place. The duration is the number of
T
ime
U
nits that the quiet
interval is to last. A TU is 1024 microseconds. Note that the wif
will continue to receive traffic, especially in the case where
promiscuous mode is enabled on the wif. Neither the host driver nor
the MAC firmware will transmit anything during this period.
set wif<1|2|3> quiet <count> <duration> <STA MAC address> – same as
the command above except that this is for remote measurement.
Notes:
channel (required)is the channel to perform the measurement on
delay (required) is the time until the start of the measurement
interval (TUs)
duration (required)is the length of the measurement
interval(TUs)
MACAddress (optional)is the MAC address of the STA that will
perform the measurement. It is local measurement if no MAC
address is set