4.2.3.27
Dynamic Frequency Selection (DFS)
start dfs
– start the dfs periodic measurement
stop dfs
– stop the dfs periodic measurement
set wif<1|2|3|*> dfs localmeasure <enable | disable>
–
enable/disable the promiscuous mode in the wif so as to
accept/reject the abort frames.
set wif<1|2|3|*> dfs remote measure <enable | disable>
–
enable/disable internal sending of the measurement request to
remote associated stations.
set dfs measurement remote period <period>
– set the time interval
between the end and start of DFS measurement procedure in seconds.
set dfs measurement remote interval <interval>
– set the time
interval between each successive measurement request sent to the
stations in seconds.
set dfs measurement remote duration <duration>
– set the duration
for which the measurement should be carried out by the station in
seconds.
set dfs measurement remote starttime <start time>
– set the time to
start the measurement after the station receives the measurement
request.
set dfs channelswitch count <count>
- sets the value after which
the channelswitch is to take place in TBTTs.
set dfs default
- load all the default values for the DFS
parameters
get dfs
– get the current values of all the DFS parameters
get dfs measurement local
– get the status of DFS local
measurement
get dfs measurement Remote
– get the status of DFS remote
measurement
get dfs measurement remote period
– get the value of DFS
measurement remote period
get dfs measurement remote interval
– get the value of DFS
measurement remote interval
get dfs measurement remote duration
– get the value of DFS