Form 44201460
16
Mar 2019
INSTALLATION
12.0)
In order to protect the ceramic glass it is recommended to only insert the ceramic glass once all the other
installation steps have been completed. The ceramic glass must be removed to wire the heater and for
commissioning.
Various means of suspending the heater can be used. See the following drawings for typical examples.
a)
Heaters installed outdoors or in areas subject to strong winds must be installed using the optional hanging
brackets or suitable rigid mount hardware. Chain, cable and other flexible hanging methods are not
recommended.
b)
Use only noncombustible materials for suspending hangers and brackets.
c)
Turnbuckles can be used with chains to allow leveling of the heater. All “S” hooks and eye bolts must be
manually crimped closed by the installer.
d)
Heaters must not be supported by gas or electric supply lines and must be suspended from a permanent
structure with adequate load capacity.
e)
Hanging points are a fixed length between centers. Secondary steel work may be required to span between
supporting beams.
f)
The appliance should be located with respect to building construction and other equipment to permit
access to the appliance for servicing etc.
f)
The heater must be installed in an adequate free area to allow the products of combustion to freely escape
from the heater. The heater must not be installed in recessed spaces or enclosure and alcoves.
g)
The heater must be suspended with its longitudinal axis horizontal, but may have its lateral axis at an angle
from 0
0
to 60
0
from the horizontal, as shown in the minimum clearances to combustibles section 4.0).
h)
An optional heat shield may be installed to reduce the top distance of clearance to combustibles. This heat
shield should be installed prior to hanging the heater. When using the heat shield at the minimum
clearance distance the angles of installation are restricted to 0, 15, 30, 45 and 60°.
i)
Use the provided angle gauge to ensure that the heater is hung at the approved installation angles.
j)
The heater can be angle mounted on both sides of its lateral axis.
k)
Hanging brackets should first be fixed to the wall surface by means of 4 lag bolts – not supplied (3/8” x 1-
1/2” minimum) through pre-formed holes in each of the brackets prior to installing heater.
Summary of Contents for 44625000
Page 37: ...Form 44201460 37 Mar 2019...
Page 45: ......