16
4. If the spraying pressure decreases more than 0.5 bar from the optimum level, pump
some more.
1. Hang the device over your shoulder.
(Fig. 11)
To prevent dripping, hold the spray wand up when first spraying and activate the
shut-off valve until no more liquid mixed with air is emerging from the nozzle.
2. If required, reset the wheel lock [12a] and activate the shut-off valve [6].
(Fig. 12)
► Spraying may now begin.
3. Make certain the optimum spraying pressure is set
(→ Table 2
) on the piston pressure
gauge [8]
(Fig. 10)
.
Preparation
Observe the instructions in the section entitled „Safety“.
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Pull up the red button on the piston pressure gauge [8] until all excess pressure is
released from the tank.
(Fig. 3)
2. Press the piston rod with handle [10] down and turn it counterclockwise.
► The piston rod with handle is locked.
(Fig. 5)
3. Unscrew the pump [2] from the tank.
(Fig. 6)
We recommend you mix the spraying liquid in the device or premix it in an external
tank: Fill to 1/3 with water, pour in the spraying agent, and then add more water until
full.
4. Add the spraying liquid to the tank [1].
(Fig. 7)
5. Check the filling level with the scale [11] on the tank.
(Fig. 7)
6. Screw the pump [2] into the tank.
(Fig. 8)
7. Press the piston rod with handle [10] down and turn it clockwise.
► The piston rod with handle is unlocked.
(Fig. 9)
8. Generate the desired pressure
(→ Table 2)
in tank
(Fig. 10).
The maximum pressure should not exceed 3 bar (red line on the piston pressure
gauge, Fig. 10). If the maximum pressure is exceeded, the safety valve will engage
and release the excess pressure.
9. Press the piston rod with handle [10] down and turn it counterclockwise. (Fig. 5)
► The piston rod with handle is locked.
+
+
Spraying
+
Observe the instructions in the section entitled „Safety“.
Operate the device only while it is vertical or suspended upright and nearly
vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the substance manufacturer!
Spraying pressure
Spraying rate with flat jet nozzle (original equipment)
1.5 bar
0.49 l/min
2.0 bar
0.56 l/min
3.0 bar
0.69 l/min
Table 2. Linear dependence: spraying rate – spraying pressure
GB
IRL
AUS
USA
NZ
CDN
IND
Summary of Contents for CLEANER 3270PE
Page 3: ...3 1a 1b 2 3 4 5 6 7 7 6 5 3 3 9 1 3 2 7 5 6 4 10 2 11 1 1 3 2 7 5 6 4 8 3...
Page 4: ...4 8 9 10 11 12 13 14 15 16 2 10 8 6 2 5 1 2 13 13 14 14 12b 12a 6 6 5 4...
Page 5: ...5 17 18 19 20 21 22 17 17 5 18 20 19 15 2 16 6 21 23 22 24 19 25 5...
Page 98: ...98 1 MESTO 1 GR...
Page 102: ...102 MESTO 2 13 15 14 16 15 17 16 18 17 19 18 20 23 24 22 23 24 21 GR 2 5...
Page 104: ...104...