17
GB
IRL
AUS
USA
NZ
CDN
IND
After usage
Observe the instructions in the section entitled “Safety”.
Observe the instructions in the section entitled “Safety”.
8VHRQO\0(672VSDUHDQGDFFHVVRU\SDUWV\RXZLOO¿QGVRPHLQWKHVSDUHSDUWV
pouch [3],
)LJDDQGE
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals. If there are no special rules, we recommend you
have the device examined externally by a competent professional every 2 years
and subject it to an internal inspection every 5 years. We would be happy to provi-
de you with an inspection schedule in German or English.
Collect and dispose of the residual liquid according to all applicable laws, requirements
and regulations. Observe the instructions of the spray product manufacturer!
Clean the protective equipment and yourself every time after usage.
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (
)LJ
.
2. Lock the pump handle in place [13].
)LJ
.
3. Unscrew the pump [2] from the tank [1].
)LJ
.
4. In the case of plant protection products dilute the remaining quantity twice in a row with
1/2 liter of water each time and spray the resulting liquid onto the treated area.
5. Empty and rinse the device with clear water.
6. Wipe off the device with a moist cloth.
7. For drying and storing the device, keep the tank and pump separate in a dry place pro-
tected from sunlight and freezing temperatures.
Care and maintenance
After using the device 50 times or at least once a year:
• Disassemble the pump [2] and grease the diaphragm [20].
)LJ
.
• Clean the nozzle [21] under running water. If required use a needle.
)LJ
5HPRYHWKH¿OWHU>@IURPEHWZHHQWKHVKXWRIIYDOYH>@DQGVSUD\OLQH>@DQGFOHDQLW
under running water.
)LJ
.
• Grease the O-rings [19] and [24]
)LJDQGRU
Faults
Fault
Cause
Remedy
No pressure builds up
in the device
The pump is not screwed on
tightly.
Screw the pump on tightly.
O-ring [19] on the pump is
faulty.
Replace the O-ring.
)LJ
.
Diaphragm [20] is defective. Replace the diaphragm.
)LJ
.
Summary of Contents for FERROX PLUS 3565P
Page 4: ...4 15 12 12 9 9 14 2 8 2 1 1 13 17 1 1 8 16 16 18 16 16 13 2 4 5 6 7 8 9 10 11 12 13 14...
Page 46: ...46...
Page 47: ...47...
Page 48: ...48...