After Usage
Observe the instructions in the section entitled "Safety".
Never leave spraying agent in the device.
1. Pull up the red piston pressure gauge handle [14] until the tank is depressurized.
(Fig. 4)
2. Lock the piston rod with handle [16].
3. Unscrew the pump [2] from the tank.
(Fig. 6)
4. Dilute the remaining quantity twice in a row with 1/2 liter of water each time and spray
the resulting liquid onto the treated area.
Collect and dispose of the residual liquid according to all applicable laws,
requirements and regulations. Observe the instructions of the spray product
manufacturer!
5. Wipe off the spraying device with a moist cloth.
(Fig. 14)
6. For drying and storing the device, keep the tank [1] and pump [2] separate in a dry place
protected from sunlight and freezing temperatures
(Fig. 14)
Clean the protective equipment and yourself every time after usage.
Care and maintenance
Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
• Unscrew the pump [2] from the tank.
(Fig. 6)
• Dismantle the pump [2].
a) Unlock the
piston
rod with handle [16].
b) Pull the piston rod with handle [16] out of the cylinder tube up to the stop and turn it
counterclockwise
(Fig. 13)
c) Disconnect the piston rod with handle [16] and the cylinder tube [2].
(Fig. 13)
• Grease the diaphragm [18].
(Fig. 15)
• Assemble the pump.
a) Push the piston rod with handle [16] into the cylinder tube.
(Fig. 16)
b) Hold the cylinder tube [2] and strongly press in the guiding plug [19] with your thumb.
(Fig. 16)
c) Pull the piston rod with handle [16] up to the stop down and turn it clockwise
(Fig. 16)
►
The guiding plug [19] snaps in.
• Lock the piston rod with handle [16] and screw the pump [2] into the tank [1].
• Clean the nozzle [13] and insert [12] under flowing water. If necessary use a needle.
(Fig. 17)
• Remove the filter [20] between the shut-off valve [7] and spray wand [8] or spray wand [9]
and clean it under running water.
(Fig. 18)
• Grease the O-rings [17] and [22]
(Fig. 15 and/or 20)
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
If there are no special rules, we recommend you have the device examined
externally by a competent professional every 2 years and subject it to an internal
inspection every 5 years.
We would be happy to provide you with an inspection schedule in German or
English.
Summary of Contents for HERBI 3232U
Page 4: ...4 8 9 10 11 12 13 14 15 16 7 16 2 14 7 16 2 7 16 5 8 7 9 1 1 3232U 2 3232 18 17...
Page 5: ...5 16 17 18 19 20 20 20 19 16 2 19 12 13 13 12 8 5 9 8 21 22 23 3232U 3232 16 3232U 3232 9...
Page 55: ...55 GR MESTO MESTO PICO 3232 HERBI 3232U HERBI 3232U BVL 30 C STO...
Page 56: ...56 GR 1 MESTO 1...
Page 60: ...60 GR 2 5 MESTO 2 17 15 18 15 21 19 14 20 18 13 17 12 17 22 23 20 23 22 20...