Care and maintenance 

 

Observe the instructions in the section entitled "Safety". 

After using the device 50 times or at least once a year: 
•  Disassemble the pump [2] and grease the diaphragm [18]. 

(Fig. 18)

 

•  Clean  the  nozzle  [20]  and  insert  [21]  under  flowing  water.  If  necessary  use  a  needle.  

(Fig. 22)

 

•  Remove  the  filter  [22]  between  the  shut-off  valve  [4]  and  hose  [6]  and  clean  it  under 

flowing water. 

(Fig. 23)

 

•  Grease the O-rings [16], [17] and [23]. 

(Figures 15, 18, 24)

 

 

Observe the legal requirements of your country for accident prevention and check 
the device in regular intervals.  
If  there  are  no  special  rules,  we  recommend  you  have  the  device  examined 
externally  by  a  competent  professional every  2  years and  subject it  to an internal 
inspection every 5 years.  
We  would  be  happy  to  provide  you  with  an  inspection  schedule  in  German  or 
English. 

 

Faults 

 

Use only MESTO spare and accessory parts.  

 

Fault 

Cause 

Remedy 

No pressure builds up in 
the device 

Cover leaking 

Close cover properly 

(Fig. 7)

 

Grease or replace O-ring [16] 

(Fig. 15)

 

The pump is not screwed on tightly  Screw the pump on tightly 

O-ring [17] on the pump is faulty  Replace O-ring 

(Fig. 20)

 

Diaphragm [18] is defective 

Replace diaphragm 

(Fig. 20)

 

Liquid is forced up out of 
the air pump 

Valve disk [19] dirty or defective  Clean or replace valve disk 

(Fig. 19) 

The nozzle does not 
spray even though 
pressure is present 

Filter [22]

 

or / and nozzle [20] 

blocked 

Clean filter 

(Fig. 23) 

or / and 

nozzle 

(Fig. 22) 

Only spray, no 
atomization 

Insert [21] is missing 

Position the insert in the nozzle 

(Fig. 22)

 

The shut-off valve does 
not close.  
Liquid emerges without 
the lever being activated. 

O-ring [23] of the pressure bolt 
is not greased / lubricated 
Faulty pressure bolt [24] or  
O-ring [23] 

Grease O-ring of the pressure 
bolt 

(Fig. 24)

 

Replace pressure bolt or O-ring 

(Fig. 24) 

 
Contact address for additional information 

 see title page

.

  

Summary of Contents for RESISTENT EXTRA 3592

Page 1: ...structions for Use 12 F CH B NL CDN Mode d emploi 18 E MEX Instrucciones de uso 24 I CH Istruzioni per l uso 30 S Bruksanvisning 36 FIN K ytt ohje 42 MESTOSpritzenfabrik ErnstStockburgerGmbH Ludwigsbu...

Page 2: ...ile Spare Parts Pi ces de Rechange Varaosat Reserve onderdelen Varuosade Pezzi di ricambio Reservdelar Reservedele RESISTENT EXTRA 3592 RESISTENT EXTRA PLUS 3592P RESISTENT EXTRA 3602 RESISTENT EXTRA...

Page 3: ...3 RESISTENT EXTRA 3592 RESISTENT EXTRA PLUS 3592P RESISTENT EXTRA 3602 RESISTENT EXTRA PLUS 3602P 1a 1b 2a 2b 3a 3b 2 5 5 5 3 3 6 4 7 3 5 1 4 6 3 4 7 5 1 6 2 5 3 3 8 6 4 8...

Page 4: ...4 4 5 6 7 8 9 10 11 12 13 10 12 14 14 11 15 4 13 10 9 11 6 10 11 10 11 10 12 16 2 2 3592 3592P 3602 3602P...

Page 5: ...5 14 15 16 17 18 19 20 21 22 23 24 17 19 18 24 17 22 20 4 2 21 23 18 20 6 4...

Page 6: ...n the exterior As of the time of manufacture there are no known harmful effects to the device caused by plant protection products approved by the German Federal Biological Institute the Biologische Bu...

Page 7: ...ccessory parts We cannot assume any liability resulting from the use of third party parts Wear suitable protective equipment when working with hazardous substances When pumping always observe the pres...

Page 8: ...excess pressure is released from the tank Fig 4 2 Raise the locking cap 10 tilt the cover 11 screw it in a clockwise direction and take out of the filling opening Fig 5 3 Hook the cover 10 11 onto th...

Page 9: ...bar from the optimum level pump some more If liquid mixed with air emerges from the nozzle the tank is empty After usage Observe the instructions in the section entitled Safety 1 Pull up the red butto...

Page 10: ...English Faults Use only MESTO spare and accessory parts Fault Cause Remedy No pressure builds up in the device Cover leaking Close cover properly Fig 7 Grease or replace O ring 16 Fig 15 The pump is n...

Page 11: ...at the discretion of MESTO replace the device itself or its defective parts If such defects are discovered please contact us immediately We require the invoice or cash register receipt for purchase o...

Reviews: