Usage 

Spraying  devices  RESISTENT  EXTRA  3592,  3602  and  RESISTENT  EXTRA  PLUS  3592P, 
3602P are designed for the spraying of forming oils and low-viscosity mineral oils, slightly alkaline 
construction chemicals (pH 

 9) as well as plant protection products, including weed killers, in the 

stipulated  concentrations.  RESISTENT  EXTRA  PLUS  3592P  and  3602P  can  also  be  used  for 
solvent-free  and  chloride-free,  neutral  cleaning  agents  as  well  as  low-viscosity,  solvent-free 
emulsion paints and paints.  
Observe  the  manufacturer’s  instructions  for  using  the  product  before  each  application.  The 
spraying devices must only be used in the exterior. 
As of the time of manufacture, there are no known harmful effects to the device caused by 
plant  protection  products  approved  by  the  German  Federal  Biological  Institute  (the 
Biologische Bundesanstalt or BBA in German).  

 

Improper use may result in dangerous injuries and environmental damage. 

You should only use other products if harmful effects on the device and endangerment of people 
and  the  environment  can  be  excluded.  Upon  request,  we  will  provide  you  with  a  list  of  active 
ingredients used in the spraying device. 

Not suitable for 

•  Combustible liquids with a flashpoint below 55 °C 
•  Hydrogen peroxide and similar substances that give off oxygen 
•  Corrosive substances (certain disinfecting and impregnating agents, acids and bases) 
•  Liquids containing ammonia 
•  Solvents and liquids containing solvents 
•  Viscous or sticky liquids or liquids that form residues (dyes, greases) 
•  Use in applications for foodstuffs 

Under no circumstances should you use 

•  external pressure sources without a MESTO compressed air valve 
•  for flaming 
•  for storing and holding liquids 
•  as an eyewash 

Safety 

 

Children and adolescents who have not been properly instructed must not use the 
device. 

 

Keep the spraying devices safe from access to children.  
Take precautions to prevent hazardous substances from being misused. 

Summary of Contents for RESISTENT EXTRA 3592

Page 1: ...structions for Use 12 F CH B NL CDN Mode d emploi 18 E MEX Instrucciones de uso 24 I CH Istruzioni per l uso 30 S Bruksanvisning 36 FIN K ytt ohje 42 MESTOSpritzenfabrik ErnstStockburgerGmbH Ludwigsbu...

Page 2: ...ile Spare Parts Pi ces de Rechange Varaosat Reserve onderdelen Varuosade Pezzi di ricambio Reservdelar Reservedele RESISTENT EXTRA 3592 RESISTENT EXTRA PLUS 3592P RESISTENT EXTRA 3602 RESISTENT EXTRA...

Page 3: ...3 RESISTENT EXTRA 3592 RESISTENT EXTRA PLUS 3592P RESISTENT EXTRA 3602 RESISTENT EXTRA PLUS 3602P 1a 1b 2a 2b 3a 3b 2 5 5 5 3 3 6 4 7 3 5 1 4 6 3 4 7 5 1 6 2 5 3 3 8 6 4 8...

Page 4: ...4 4 5 6 7 8 9 10 11 12 13 10 12 14 14 11 15 4 13 10 9 11 6 10 11 10 11 10 12 16 2 2 3592 3592P 3602 3602P...

Page 5: ...5 14 15 16 17 18 19 20 21 22 23 24 17 19 18 24 17 22 20 4 2 21 23 18 20 6 4...

Page 6: ...n the exterior As of the time of manufacture there are no known harmful effects to the device caused by plant protection products approved by the German Federal Biological Institute the Biologische Bu...

Page 7: ...ccessory parts We cannot assume any liability resulting from the use of third party parts Wear suitable protective equipment when working with hazardous substances When pumping always observe the pres...

Page 8: ...excess pressure is released from the tank Fig 4 2 Raise the locking cap 10 tilt the cover 11 screw it in a clockwise direction and take out of the filling opening Fig 5 3 Hook the cover 10 11 onto th...

Page 9: ...bar from the optimum level pump some more If liquid mixed with air emerges from the nozzle the tank is empty After usage Observe the instructions in the section entitled Safety 1 Pull up the red butto...

Page 10: ...English Faults Use only MESTO spare and accessory parts Fault Cause Remedy No pressure builds up in the device Cover leaking Close cover properly Fig 7 Grease or replace O ring 16 Fig 15 The pump is n...

Page 11: ...at the discretion of MESTO replace the device itself or its defective parts If such defects are discovered please contact us immediately We require the invoice or cash register receipt for purchase o...