19
English
Problem
Possible Cause
Solution
Air is leaking from the
compressor.
The hose connection is loose or
improperly sealed.
The air hose is broken or damaged.
Ensure connections are sealed with thread
sealing tape and tightened.
Replace the air hose.
The compressor runs
continuously.
The tank drain valve is open.
The pressure switch is defective.
The usage is excessive.
Ensure the tank drain valve is closed.
Take the compressor to a service center.
Decrease the amount of tool run-time; the
compressor is not large enough to supply the
air requirement of the tool.
The compressor
vibrates.
The compressor mounting bolts are loose. Tighten mounting bolts.
The air output is lower
than normal.
The inlet valves are broken.
The connections are leaking.
Take the compressor to a service center.
Apply thread sealing tape to
fi
tting and
tighten.
Regulator knob has
continuous air leak.
Regulator will not shut
o
ff
air outlet.
Regulator is damaged.
Take the compressor to a service center.
000Book̲EC1315S.indb 19
000Book̲EC1315S.indb 19
2020/12/17 13:43:11
2020/12/17 13:43:11