23
English
STORAGE
Storing in a place below 104°F (40°C) and out of the
reach of children.
NOTE
Storing lithium-ion batteries
Make sure the lithium-ion batteries have been fully
charged before storing them.
Prolonged storage (3 months or more) of batteries with
a low charge may result in performance deterioration,
signi
fi
cantly reducing battery usage time or rendering
the batteries incapable of holding a charge.
However,
signi
fi
cantly reduced battery usage time
may be recovered by repeatedly charging and using
the batteries two to
fi
ve times.
If the battery usage time is extremely short despite
repeated charging and use, consider the batteries
dead and purchase new batteries.
SERVICE AND REPAIRS
All quality compressors will eventually require servicing
or replacement of parts because of wear and tear from
normal use. To assure that only genuine replacement parts
will be used, all service and repairs must be performed by
a metabo HPT AUTHORIZED SERVICE CENTER, only.
CAUTION
In the operation and maintenance of power tools,
the safety regulations and standards prescribed
in each country must be observed.
NOTE:
Speci
fi
cations are subject to change without any
obligation on the part of the metabo HPT.
Important notice on the batteries for the
metabo HPT cordless power tools
Please always use one of our designated genuine
batteries. We cannot guarantee the safety and
performance of our cordless power tool when used
with batteries other than these designated by us, or
when the battery is disassembled and modi
fi
ed (such
as disassembly and replacement of cells or other
internal parts).
TROUBLESHOOTING GUIDE
WARNING
●
To avoid injury from an accidental start, turn the power switch OFF and remove the plug from the power
source or remove the battery or AC/DC adapter from the main body before making any adjustments.
●
All electrical or mechanical repairs should be done only by quali
fi
ed service technicians. Contact
metabo HPT Authorized Service Center.
1. Cordless Air Compressor
Problem
Possible Cause
Remedy
The compressor does
not run.
Loss of power or overheating.
There is no electrical power being supplied
to compressor or the power switch is in the
OFF position.
Thermal overload open.
The power switch is bad.
Tank is full of air.
Check for proper use of battery.
Check to be sure the battery is installed in
and the power switch is in the ON position.
First remove the battery and wait until it
becomes cool.
Replace the power switch.
Compressor will turn on when tank
pressure drops to cut-in pressure.
00Book̲EC36DA̲NA.indb 23
00Book̲EC36DA̲NA.indb 23
2021/07/08 9:36:18