20
English
(2) Power switch OFF
Under the condition of “Power switch ON”, push
and hold on Power switch more than 1 second, then
power indicator goes o
ff
.
Under the condition of “Power switch ON”, functions
below are active.
(3) Information indicator
In case of operation error, LED lamps show as below.
Status of indicator
1 LED (Red) blinks
The battery remaining
power is nearly empty.
Recharge the battery as
soon as possible.
2 LEDs (Red) blink
2 LED lights blink in an
interval.
•
In case of too hot
condition, Blink in
0.5 second interval.
•
In case of too cold
condition, Blink in
0.25 second interval.
After 10 seconds, LED
lights and Power switch
automatically turn o
ff
.
Machine is in too cold
(below 23°F (-5°C) or too
hot condition.
Allow the nailer to cool
or warm-up thoroughly in
adequate condition.
2 LEDs blink in Orange,
after about 10 seconds,
automatically turn o
ff
Power switch.
Contact metabo HPT for
inspection.
TESTING THE NAILER
DANGER
●
Operators and others in
work area MUST wear safety
glasses with side shields
which conforms to ANSI Z87.1
speci
fi
cations.
WARNING
●
Make sure the trigger is locked when not
fi
ring nails.
This Nailer has a lock mechanism to prevent the
nails from being
fi
red.
Set the lock lever at the position to lock the
trigger.
Slide the lock lever to the position when the
Nailer is to be used, and to the position when it
is not in use.
Trigger
Lock lever
Lock position
Free position
●
Never use Nailer unless push lever is operating
properly.
The machine employs a preventive mechanism
for unloaded operation.
The machine enters a state where the push lever
cannot be pushed up. This takes place when the
magazine is not loaded with nails or when the
remaining number of nails becomes less than 5.
CAUTION
●
Use caution not to throw the push lever tip onto
wood.
Before actually beginning the nailing work, test the Nailer
by using the checklist below. Conduct the tests in the
following order.
If abnormal operation occurs, stop using the Nailer
and contact a metabo HPT authorized service center
immediately.
(1) REMOVE ALL NAILS AND BATTERY FROM
NAILER.
□
ALL SCREWS MUST BE TIGHTENED.
□
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY with pulling back the feeder knob.
Trigger
Push lever
Feeder knob
000Book̲NR3665DA̲metabo.indb 20
000Book̲NR3665DA̲metabo.indb 20
2021/02/22 12:20:25
2021/02/22 12:20:25