10
ENGLISH
Air tool is not supplied with sufficient
pressure.
•
Pressure regulator not opened wide
enough.
−
Open pressure regulator more.
•
Hose connection between compres-
sor and air tool leaky.
−
Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Power tools in need of repair can be sent
to one of the adresses listed on the sec-
ond-last page.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7.
Repairs
8.
Environmental Protection
9.
Technical Specifications
Suction capacity
l/min
235
Free air delivery (volume flow rate)
l/min
125
Filling rate
l/min
145
Working pressure (compression end pressure)
bar
8
Pressure vessel volume
l
24
No. of air outlets
2
Pump model
F 245
No. of cylinders
1
Motor speed
min
-1
2850
Motor capacity
W
1.5
Supply voltage (50 Hz)
V
230
Rated current
A
6.8
Fuse protection min.
A
10 (time-lag)
Degree of protection
IP 20
Max. overall cable length when using extension cables:
– at 3 x 1.0 mm
2
lead cross section
– at 3 x 1.5 mm
2
lead cross section
– at 3 x 2.5 mm
2
lead cross section
m
m
m
10
25
25
Dimensions length x width x height
mm
675 x 355 x 645
Weight
kg
25.5
Sound pressure level at 1 m max.
dB (A)
87 ± 3