ENGLISH
14
to re-
quired working pressure. The cur-
rent working pressure is indicated
by the regulated pressure gauge
A
Caution!
The regulated pressure may not be set
higher than the max. working pressure
of the connected air tools!
3. Connect air hose to compressed air
outlet
4. Connect air tool. You are now ready
to work with the air tool.
5. Switch the compressor OFF
you do not continue working imme-
diately afterwards. Unplug after
switching OFF.
6. Drain condensation water from
pressure vessel once a day
A
Danger!
Prior to all servicing:
– Switch machine OFF.
– Unplug power cable.
– Wait until the compressor has come
to a complete stop.
– Ensure the compressor and all air
tools and accessories connected to
it are relieved from pressure.
– Let the device and all air tools and
accessories cool down.
After all servicing:
– Check to see that all safety devices
are operational.
– Make sure that no tools or other
parts remain on or in the machine.
Repair and maintenance work other
than described in this section must
only be carried out by qualified spe-
cialists.
5.1
Important Information
Maintenance and inspections must be
planned and carried out appropriately
for the setup and operating mode of the
machine in accordance with legal regu-
lations.
Regulatory authorities may request
submission of the corresponding docu-
mentation.
5.2
Periodic maintenance
Prior to each use
•
Check air hoses for damage, re-
place if necessary.
•
Check all screwed connections for
tightness, tighten if necessary.
•
Check power supply cable for dam-
age, if necessary have replaced by
a qualified electrician.
Every 50 hours of operation
•
Check air filter element
of com-
pressor pump, clean if necessary.
•
Check the oil level in the compres-
sor pump with the oil dip stick
and refill oil if necessary.
Every 250 operating hours
•
Replace air intake filter element of
compressor pump.
Every 500 operating hours
•
Drain oil and fill with fresh oil.
Every 1000 operating hours
•
Have unit serviced by an authorized
service station. This will extent the
compressor's service life consider-
ably.
5.3
Saw storage
1. Switch unit OFF and unplug.
2. Release pressure from tank and all
connected air tools.
3. Drain condensate from pressure
vessel .
4. Store machine in such way that it
cannot be started by unauthorized
persons.
A
Caution!
Do not store or transport machine un-
protected outdoors or in damp environ-
ment.
Do not lay machine on its side for trans-
portation or storing.
5.
Care and Maintenance
46
47
44
45
48
49
50
51
Summary of Contents for ClassicAir 255
Page 55: ...55 1 1 2 3 6 7 12 5 9 10 11 8 4 1 2 3 4 5 6 7 8 9 10 11 12 I_0019el2A fm 1 2 10...
Page 57: ...57 A B A A A A A B...
Page 59: ...59 4 2 B 4 3 1 44 48 2 45 47 A 3 46 4 5 44 6 49 A 5 1 5 2 43 5 46 47 44 45 48 49...
Page 60: ...60 50 50 51 250 500 1000 5 3 1 2 3 4 A A 50 51 6...
Page 62: ...62 kg 27 l LPA 1 m dB A 87 3 LWA dB A 94 20 C...
Page 98: ...98 1 1 2 3 6 7 12 5 9 10 11 8 4 1 2 3 4 5 6 7 8 9 10 11 12 I_0019ru2A fm 1 2 10...
Page 100: ...100 A B A A A A A B...
Page 102: ...102 2 42 41 43 4 2 B 4 3 1 44 48 2 45 47 A 3 46 4 5 44 6 49 A 5 1 41 42 43 46 47 44 45 48 5 49...
Page 103: ...103 5 2 50 50 51 250 500 1000 5 3 1 2 3 4 A A 50 51 6...
Page 105: ...105 x x 555 310 600 27 LPA 1 A 87 3 LWA A 94 20 C...