22
Opening of the boiler door or flue
leakiness
cannot
expose
the
regulator directly to hot gases and
fire from the fireplace.
In case of using the version with
STB device before making the
montage and wiring it is strongly
recommended to take out the STB
capillary from inside the clamp box
using cable opening as described on
the picture below.
Attention! This capillary cannot
be smashed or bend with acute
angle.
1- Cable opening 2 – The STB capillary cable,
which was being correctly taken out from the
clamp box.
12.4
IP protection rate
The regulator casing provides the IP20
protection rating. The casing on the
connectors cover side provides IP00 rating,
and because of that connectors must be
unconditionally covered with the cover.
If there is a need to gain an access to the
terminals side, it is a must to disconnect the
mains voltage and make sure there is no
dangerous voltage on regulator terminals.
12.5
Electric connection
The regulator is designed to be fed with
230V~, 50Hz voltage. The electrical system
should be:
three core (with protective wire PE),
in accordance with applicable regulations.
Caution: After the regulator is
turned off using the keyboard,
dangerous voltage can occur on the
terminals. Before starting any
assembly
works,
you
must
disconnect the mains supply and
make sure that there is no
dangerous voltage on the terminals
and the leads.
Connection cables should not have contact
with surfaces which temperature exceeds
cables nominal operating temperature.
Terminals 1-22 are designed to connect
devices supplied by the mains 230V~
voltage. Terminals 25–48 are designed to
work with low-voltage devices (<12V).
Connection of the 230V~ mains
voltage to terminals 25-48 or to
transmission terminals G2, G3, B
and USB results in the regulator
damage and poses a threat of
electrocution.
Tips of connection cables, especially mains
voltage cables should be secured from
splitting by e. g. insulated clamp sleeves in
accordance with the picture below: a –
properly secured, b – improperly secured.
Unconditionally check if any lead of
the insulated cable, or the cable
itself DO NOT have electrical
connection
with
the
metal
grounding strip (which is placed
near to high voltage terminals of
the regulator).
The feeder cable should be connected to the
terminals marked with an arrow.
Insulated clamp sleeve, 6mm lenght.
Insulated clamp sleeve, 6mm
lenght.