Electrical 

Cabinet Location 

INSTALLATION

Install the unit in an indoor well-ventilated area for better efficiency.  For best performance
 maintain 4” clearance on the back and sides of the unit.  Do not use unit outdoors.

  

• Avoid installation in a high humidity and/or dusty area.  Humidity can cause unit to rust 

clean condenser at least once a month with a brush or clean cloth.  Malfunction due to 

 dirty condenser will void warranty.

  Select a location away from heat and moisture-generating equipment.  High ambient 

     temperatures will cause the compressor to overwork, leading to higher energy bills and 

•   Install the unit on a strong and level surface.  Unit may make loud noises or may 

• Ensure that the required voltage of the compressor is being supplied at all times.  Low or 

high voltage can be detrimental to the refrigeration unit.  
All units should be connected into a grounded and properly sized electrical outlet with 

  

of the unit.  

The temperature controls are factory-set to maintain an average temperature of 38°F in

If you have questions regarding the grounding connection contact your dealer. 

Shelves have been factory installed for your convenience.  Before loading shelves be sure that all 

and will decrease its efficiency.  Dust collected on condenser coil will cause a malfunction.  

IMPORTANT!!  MUST READ BEFORE INSTALLATION

If the unit has recently been transported please let unit stand motionless for a minimum 
period of 24 hours before plugging it in.

Confirm the unit drops down to desired temperature before loading with product.

Install unit where there is proper ventilation in the area where it will operate.

Do not plug in unit until all accessories are installed (shelves, shelf clips, casters).

Please read through the manual in its entirety.

   malfunction if the installation surface is uneven.

     gradual breakdown of unit.  Malfunction due to high ambient temperature will void warranty.

appropriate over-current protection.  Refer to the electrical requirements on the nameplate 

Temperature Controls

refrigerators and 0F in freezers.  To maintain a different temperature, simply adjust the
control knob located inside the unit.  To decrease the temperature (colder), turn clockwise,
to increase the temperature (warmer), turn control knob counter-clockwise.

CAUTION
Setting the temperature control to the coldest setting may cause the evaporator coil to
freeze and ice up.  This will eventually result in a warmer cabinet temperature.

Loading Product

shelf clips are completely fastened in their correct locations.  It is important that all shelves rest
completely level before stocking your cabinet with product.

In order to maintain correct air flow inside the unit, be sure to leave 4” of space between the back

wall and stored product.  Blocking the evaporator fans will result in a warmer cabinet temperature

ultimately compressor failure.

Refrigerator coils are kept below the freezing point (32°F).  During compressor downtime

Defrost Systems

the evaporator fan continues to circulate air through the evaporator coil.  This air circulation
raises the coil temperature above the freezing point, melting any accumulated frost.  Runoff
water is drained into the evaporator pan and evaporated.  Freezer coils are defrosted 
electrically.  Automatic defrost timers are built-in to the refrigeration system and may not be
adjusted.  The defrost timers automatically initiate at pre-set intervals and for a pre-determined
duration.

PLEASE NOTE: Excessive door openings should be avoided in order to maintain cabinet

temperature and to eliminate the possibility of coil freeze up.

OPERATION

Ensure that the unit has its own dedicated outlet.  Do not use an extension cord. 