Maintenance and repair
AKM-Series 220 | Version 1.07
23
Fig. 30: Check oil level
Refill or replace hydraulic oil.
When refilling, always use the same type of hydraulic oil
that has already been filled. Do not mix hydraulic oils
from different manufacturers. Only use hydraulic oil spe-
cified in accordance with DIN 51524-2 when refilling.
Oil specification according to DIN 51524-2
Depending on the model, the empty hydraulic oil tank
has a volume of 22 or 35 litres. Only use hydraulic oil
specified according to DIN 51524-2 in the hydraulic sy-
stem. Select the viscosity class according to the local
ambient temperature. Observe the following list.
The corresponding hydraulic oils are available under
the following manufacturer specifications:
10.2.2 Lubrication diagram
WARNING!
There is a risk of injury from oil splashing out under
pressure. Damage to health caused by incorrect
handling of hydraulic oil is possible.
- Always wear safety glasses, gloves and protective
clothing.
- Avoid direct contact with hands, skin and eyes.
- First switch off the machine at the main switch and
take suitable measures to prevent it from being
switched on again accidentally. A suitable measure
is, for example, the attachment of a warning sign.
ATTENTION!
- When refilling, always make sure that the oil drain
plug is properly inserted and tightened before fil-
ling the hydraulic oil.
- If the hydraulic oil is to be replaced, place an oil
tray under the oil drain plug. When selecting the oil
tray, ensure that there is a maximum of 36 litres of
oil in the oil tank.
- When filling, make sure that the hydraulic oil does
not run to the ground and that there is a danger
point. Use a funnel as a preventive measure.
- If the oil temperature is high, allow the entire hy-
draulic system to cool down before refilling or
changing.
- Observe the danger area.
Fill level sight glass
ATTENTION!
- Slowly open the cap of the oil tank to balance the
pressure!
- Observe the level gauge when filling with oil. Fill the
oil only up to the upper mark.
- Hydraulic oil is flammable. Do not use an open fire
while refilling or replacing hydraulic oil.
- Do not inhale vapours that may escape from the hy-
draulic system.
- Dispose of used oil in accordance with the cur-
rently valid legal regulations.
Standard
Ambient tempera-
ture below 20°C
Ambient tempera-
ture above 20°C
DIN 51524-2
ISO-VG class 32
ISO-VG class 46
Manufacturer
Ambient tempera-
ture below 20°C
Ambient tempera-
ture above 20°C
ARAL
VITAM GF 32
VITAM GF 46
BP ENERGOL
HLP-
HM 32
ENERGOL HLP-
HM 46
ESSO
NUTO H 32
NUTO H 46
SHELL
TELLUS 32
TELLUS 46
CASTROL
HYSPIN AWS 32
HYSPIN AWS 46
Nr
Lubrication
point
Lubricating
interval
Oil type
1
Guide
spindle,
Nipple
monthly
Grease
2
Hydraulic
tank
if necessary
ISO VG 32 -
ISO VG 46
Summary of Contents for 3834200
Page 32: ...www metallkraft de ...