OPERATION MANUAL
All precautions must be taken to keep the hydraulic system clean at all times
When changing oil, make sure that the top of the oil tank is clean and free from dust and dirt.
q
Remove the oil tank cover (Fig 6.5)
q
Using an appropriate pump, drain out the old oil completely. Be sure nothing is left
q
Using a pump, add the new oil into the tank.
q
Oil level must be filled until the oil reaches the top mark of the oil indicator.
q
Always keep the oil at the same level.
q
Oil must be changed after the first 200 working hours of use, and then after every 1000 working
hours (See: Lubrication Diagram Fig. 6.4).
6.3 CHANGING THE HYDRAULIC OIL
Fig. 6.5
Filler Cap
Sight Glass
Oil Tank Cover
Page 24
Instructions Manual for HG-4012 (S948)
12/02/2018