11.4 SIGNAL MODULES - S - DIGITAL O ELECTRICAL POWER SUPPLY
TECHNICAL DATA
6 M8 Digital O Electrical power supply
Supply voltage range
VDC
12 -10% 24 +30%
Minimum operating voltage
VDC
10.8
*
Maximum operating voltage
VDC
31.2
Maximum admissible voltage
VDC
32
***
Output voltage
Corresponding to power voltage
Current for each connector
mA
max 1000
Current for each module
mA
max 4000
Type of output
Software-configurable PNP/NPN
Protection
Overload and short-circuit protected inputs
Connections
6 M8 3-pole female connectors for Signals
1 M8 4-pole male connector for Supply
Input active signals
One LED for each input
* Minimum voltage 10.8VDC required at solenoid pilots. Check the minimum voltage at the power suply output using the calculations see page 31.
***
IMPORTANT! Voltage greater than 32VDC will damage the system irreparably.
11.5 SIGNAL MODULES - S - ANALOGUE INPUTS
TECHNICAL DATA
4 M8 Analogue Inputs
Sensor supply voltage
Corresponding to power voltage
Current for each connector
mA
max 200
Current for each module
mA
max 650
Type of input, software configurable
0/10 VDC; 0/5 VDC; +/-10 VDC; +/-5 VDC; 4/20 mA; 0/20 mA
Protection
Overload and short-circuit protected inputs
Connections
4 M8 4-pin female connectors
Local diagnostic signal via LED
Overload, short-circuit or type of input
not complying with the configuration
Digital convert resolution
15 bit + prefix
11.6 SIGNAL MODULES - S - ANALOGUE OUTPUTS
TECHNICAL DATA
4 M8 Analogue Output
Supply voltage for devices
Corresponding to power voltage
Current for each connector
mA
max 200
Current for each module
mA
max 650
Type of output
0/10 VDC; 0/5 VDC; +/-10 VDC; +/-5 VDC; 4/20 mA; 0/20 mA
Protection
Overload and short-circuit protected outputs
Connections
4 M8 4-pole female connectors
Local diagnostic signal via LED
Overload, short-circuit or type of connection
not complying with the configuration
Digital convert resolution
15 bit + prefix
Summary of Contents for EB 80 ETHERNET POWERLINK