CONNECTING THE UNIT 

CAUTION: A 5-micron filter (TSD800-6) ,not included,  must be installed with the unit to 
ensure proper air filtration. 

 

 

 

 
 

 

 
 
 
 
 
 

 

 
Figure 2.0 

 

 
 
 
 
 
 
 
 
 

 
6

 

SETUP INSTRUCTIONS 

Refer to Figure 1.0  

6.1

 

Manual/Purge Dispense Cycle Setting: 

1.

 

Turn on the unit by pressing the Power button (1).   

2.

 

Press the Mode button (2) until “PURGE” appears on the Display. 

3.

 

Turn up the air pressure by rotating the Air pressure regulator knob (5) until 
the desired pressure is indicated on the Display.   

4.

 

After filling the barrel or using pre-packaged adhesive, attach syringe to 
receiver head assembly.  Make certain that the syringe locks into place. 

5.

 

Connect the plug end of the receiver head assembly to one of the air 
dispense outlet (6). 

6.

 

If vacuum “suck back” is needed, rotate the Vacuum regulator (7) counter 
clockwise until the desired vacuum pressure is indicated on the Display. 

7.

 

Press and hold the Foot switch to activate dispensed cycle. (The 
Manual/Purge Mode is now activated) 

 

6.2

 

 Automatic Dispense Cycle Setting 
6.2.1 Program selection 

1.

 

Press the reset button (3) until “P:” is flashing 

2.

 

Rotate the Setup Control Knob (8) to select desired program 

6.2.2 Timed Mode setting 

1.

 

Press the Mode button (2) to select “TIMED” mode 

2.

 

Press and release the reset button (3) until the colon (:) in the 
“TIME:” is flashing  

Items 

Description 

To Air Source 

Air Filter (not included) 

Power Adapter 

Foot Switch 

 

6

 

3.

 

Rotate the Setup control knob (8) to set the desired dispense time  

4.

 

Depress Foot switch to activate timed dispensed cycle 

 

6.3

 

Teach Mode Setting  

In the teach mode, the unit will accumulate time as long as the foot switch is 
depressed.  This is helpful in determining dispense time required when 
dispense output is unknown. 
1.

 

Press the Mode button (2) to select “TEACH” mode 

2.

 

Press and release the reset button (3) until the dispense time = 0.000S    

3.

 

Press and hold down Foot switch.  Dispense time will accumulate 
during this time 

4.

 

Release Foot switch when proper amount of fluid is dispensed 

5.

 

Press the Mode button (2) to switch the “TIMED” mode 

6.

 

The dispenser is now set to repeat this time cycle. 

 

6.4

 

Multiple Shots Setting:  

Up to ten separate individual or sequenced shots can be stored in the DX-
350/DX-355. 
1.

 

Follow steps in section “6.2 Automatic Dispense Cycle Setting” to set 
dispense time in desired programs  

2.

 

Press both the Reset button (3) and the Power button (1) 
simultaneously to activate sequence program mode   

3.

 

Rotate the Setup Control knob to select total number of program to be 
dispensed in sequence 

4.

 

Press both the Reset button (3) and Power button (1) to exit Multiple 
Shots mode 

 

6.5

 

Cycle Counter 

The  cycle  counter  records  the  numbers  of  automatic  dispense  cycle  being 
activated.  Up to 65,535 cycles can be recorded.  This number is shown at 
the lower right hand corner of the LCD.  To reset the counter, press and hold 
the  Reset  button  (3)  and  the  Mode  button  (2)  simultaneously  until  the 
counter shows “0”. 

 

6.6

 

Change Pressure and Vacuum Unit Display 

1.

 

Press and release the reset button (3) until the colon (:) in the 
“PRESSURE:” or “VACUUM:” is flashing 

2.

 

Rotate the Setup control knob (8

to select desired unit display 

 
 

 

 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for DX-355

Page 1: ...following actions Making changes to equipment that has not been recommended in the User Guide Using incompatible or damaged replacement parts Using unapproved accessories or auxiliary equipment 1 2 Safety Precautions Do not operate this unit in excess of maximum ratings settings Always wear appropriate personal protective clothing or apparel Use only the following power adaptor models PSA15R 240P ...

Page 2: ...0 for temperature up to 31 C 87 8 F Decreasing linearly to 50 relative humility at 40 C 104 F Air Output DX 350 0 100 psi 0 6 9 bar DX 355 0 15 psi 0 1 03 bar Vacuum 406mm 16 of Hg Timer 0 008 60 000 seconds Cycle Mode Timed Interrupt Teach Purge Timing Repeat Tolerance 0 001 Cycle Rate 1 200 cycles min LCD 20 X 4 display segments 4 4 FEATURES Figure 1 0 Items Description 1 Power Button 2 Mode But...

Page 3: ...Depress Foot switch to activate timed dispensed cycle 6 3 Teach Mode Setting In the teach mode the unit will accumulate time as long as the foot switch is depressed This is helpful in determining dispense time required when dispense output is unknown 1 Press the Mode button 2 to select TEACH mode 2 Press and release the reset button 3 until the dispense time 0 000S 3 Press and hold down Foot switc...

Page 4: ...he following recommendations should be followed 1 Make certain air supply is clean and dry 2 Avoid turning barrels upside down or laying barrel so that material may run through air line to internal components 3 Avoid connecting the unit to excessive moisture or solvent saturation 4 Avoid connecting air supply exceeding 100 psi 6 9 bar for the DX 350 and 15 psi 1 03 bar for the DX 355 5 Use only Am...

Page 5: ...DC range and a maximum of 250 mA Note During the dispense cycle pin 3 will be grounded Please make sure the external device your machine that controls the dispenser controller has the same ground as the DX 350 355 controller Pin 7 8 and 9 Available Chasis Ground To initiate a dispense cycle with contact closure When low pressure alarm is triggered Pin 4 is grounded When low pressure alarm is turne...

Reviews: