Installation Manual
MX15 Series
9
Figure 2-2: Location of AC Input Fuse Block, Chassis Ground Connection, and Output Terminal
Block
Note: To comply with product safety requirements, EARTH GROUND must be connected
to the chassis of the AC power system using the ground stud located above the K1
relay. Use a Green/Yellow ground wire.
The mains source must have a current rating equal to or greater than the input fuses and the
input wiring must be sized to satisfy the applicable electrical codes. The front cover must be re-
installed prior to use and the strain relief provisions located at the rear bottom of the unit must be
used to maintain protection against hazardous conditions.