Installation Manual - Rev C
California Instruments
MX15 Series
22
P8 / P9
Description
20
300 VRNG: 300 V AC Range Select
21
COM:
Common. Signal return.
22
/REM OFF: Remote Off Control not
23
COM:
Common. Signal return
24
FLK/BYP: Flicker / Bypass OMNI control
25
/OVL:
Overload not
26
CLA:
Current Limit A. Programmed current limit reference for phase A
27
CLC:
Current Limit C. Programmed current limit reference for phase C (Not Used)
28
CSB:
Current Sum Phase B. (Not Used)
29
N/C
30
FLT B:
Amplifier Fault Phase B (Not Used)
31
N/C
32
DC:
DC mode control
33
INP OFF:
Input power control
34
A ERR HI: Error Signal Phase A, high
35
N/C
36
B ERR LO: Error Signal Phase B, low (Not Used)
37
C ERR HI: Error Signal Phase C, high (Not Used)
2.7.2 Analog Input Connector
Input screw-terminal strip. Functions are called out on rear panel decal. Table shows connections
from left to right when standing at the rear of the MX cabinet.
Table 2-4: Analog Interface Connector
Pin
Description
1
RPV HI.
INPUT: Analog input for External Modulation
2
RPV Lo.
INPUT: return.
3
EXT SYNC HI
INPUT: Analog input for external sync mode.
4
EXT SYNC Lo
INPUT: return.
5
RI:
INPUT: Remote Inhibit. (Contact closure).
6
RI:
INPUT: return.
2.7.3 BNC Connectors
BNC connectors. Functions are called out on rear panel decal. Table shows connections from left
to right when standing at the rear of the MX cabinet.
Table 2-5: BNC Connectors
Summary of Contents for MX15
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank ...
Page 14: ...Installation Manual MX15 Series 10 Figure 2 3 MX15 AC Input Connection Diagram ...