www.metel.eu
7.3
Topology Optical Ring Complying with CSN EN 50131-1 ed.2.
Default switch setting
200 and 2G-RS.E
Other switches
Ring enabled
Yes
Yes
Ring ID
0
0
Relay
Set to ring
interruption detection
(RING-OK)
RS485 port setting
9600kbps
8-N-1
9600kbps
8-N-1
Setting of Tx and Rx address
for port RS485
Rx: 239.192.168.1
Tx: 239.192.168.1
Rx: 239.192.168.1
Tx: -
When using the switches as transmission route in alarm systems it is necessary to:
7.3.1
Set one switch to MASTER mode
7.3.2
When using DOMINUS alarm systems set RS485 port to DOMINUS mode
(19.2kbps, 9-N-1 line reset support).
7.3.3
In case of interconnection of 2G and 200-RS.E switches with Ethernet switches
we recommend setting of packet filtering according to source MAC Addresses. The
filtering guarantees safe separation from the surrounding network.