www.metel.eu
8
Switch Configuration
8.1
IP Address, Mask and Gateway
8.1.1 Every switch has pre-set default configuration with mask 255.255.255.0 and
following IP addresses:
200M-RS.E4
10.19.0.x
2G-RS.E4
10.16.0.x
200M-RS.E5
10.20.0.x
2G-RS.E5
10.17.0.x
200M-RS.E6
10.21.0.x
2G-RS.E6
10.18.0.x
200M-2.0.1.E 10.22.0.x
2G-2.0.1.E
10.23.0.x
200M-2.1.4.E 10.9.0.x
2G-2.1.4.E
10.10.0.x
200M-2.0.4.ECA 10.24.0.x
2G-2.3.0.E
10.15.0.x
200M-2.0.4.ECB 10.25.0.x
2G-0.1.4.E
10.13.0.x
2G-0.1.8.E
10.14.0.x
x – corresponds to the last number of MAC address.
Please change the IP address if required. See the figure below.
8.1.2 Run application SIMULand (available on the website
www.metel.eu
)
8.1.3 Select menu „Project/Find devices“. Your computer must have a valid IP address
which is in the range used by the switches (default: 10.xxx.xxx.xxx and mask
255.255.255.0). Please check firewall settings if no device was found. A new rule
must be created for SIMULand or Firewall must be turned off.
8.1.4 Select „Project/Find devices“ (Remote management)
7/11