74 | 120
blue’Log X series
14.3
Active power procedure
Control values for inverter active power control or active power regulation can be
determined using various procedures. In addition to the procedures, options are made
available which allow further settings to be specified (e.g. the Intelligent Power Limit
function allows a closed control loop to be enabled).
Fig. 59: Power Control: Active power regulation
Input box
Meaning
Procedure
Selects the active power procedure
Cog button
Brings up the configuration settings for the selected
active power procedure
Enable Intelligent
Power Limit (IPL)
Enables the IPL function (see Section 14.3.4 Intelligent
Power Limit (IPL))
Gradient limitation P
procedure
Enables adjusting the changing rate of the P control
values
Zero up only
Gradient limitation is active only if the previous active
power limitation was 0%
Up only
Gradient limitation is active only during increase of active
power limitation
Fully on
Gradient limitation is always active during decrease or
increase of the active power limitation
Gradient
Specifies how high the maximum rate of change in the
active power can be per second