blue’Log X series
15 | 120
5.2
Cables and wiring
Recommended cable types for wiring the individual system components are given
below. The restrictions resulting from the wiring are also listed.
5.2.1
Permitted cable types for the blue’Log power supply
Connecting cable
Voltage range
Cable cross
section
Type
Finely stranded
conductor
U < 24 V DC
1 mm
2
H05V-K
Finely stranded
conductor
U >= 24 V DC
0.75 mm
2
H05V-K
5.2.2
Cable types for device connections
Bus cabling (inverters, current sensors)
Recommended: Data cable (twisted and shielded)
Alternatively: Network cable
Li2YCYv (TP) 2×2×0.5mm
2)
1)
CAT 6-SFTP
Analog signals (irradiance sensor, temperature sensor)
Sensor cable
LiYCY 2×2×0.5mm
2
Digital signals (energy meter, remote control system)
Sensor cable
LiYCY 2×2×0.5mm
2
Ethernet network
Network cable
CAT 5 / CAT 6