7
LP-80
Figure 7 The base of the probe is in the center of the row and the end is in the center of the open space
between rows. When sampling the next row, the same orientation is maintained, giving an accurate
representation of the overall area.
2.2.2 MANUAL MEASUREMENTS
1. Navigate to the PAR tab.
2. To make an above-canopy PAR measurement, press
UP.
The resulting value displays in the upper right section of the screen.
3. To make measurements below the canopy, plug in a external sensor or take an above
canopy PAR reading first before the summary data can update. If the external sensor is
attached, the LP-80 records both above- and below-canopy readings pressing either the
UP or DOWN.
4. To make measurements below the canopy, press
DOWN or PAR-LAI in the upper right
corner of the keypad.
The LP-80 recalculates summary data after each below-canopy PAR reading. Other
relevant data displays at the bottom of the screen (
).
Figure 8 Active PAR measurement screen