background image

2

USING APOGEE UV SENSORS WITH ZENTRA SYSTEM

1.  INTRODUCTION

Apogee Instruments SU-221 Ultraviolet (UV) Radiation sensors are designed for continuous 
UV radiation measurement in either indoor or outdoor environments. The Apogee UV sensor 
detects UV radiation from 300 to 400 nm, which lies primarily in the UV-A portion of the UV 
spectrum (315 to 400 nm).

The information in this document explains how to install the required hardware to mount 
Apogee UV sensors that have been preconfigured by METER Group to work seamlessly with 
METER ZENTRA series data loggers. Details of how the ZENTRA system handles the data are 
also included. Please read this document carefully in its entirety before going out to the field. 

For more information on Apogee sensors, please review the 

Ultraviolet-A Radiation Sensor 

User Manual

 or visit the 

Apogee UV sensor product page

 (apogeeinstruments.com/uv).

2.  INSTALLATION

Follow the steps listed in 

Table 1

 to install Apogee sensors in the field. A cable, mounting 

bracket, leveling plate, and screws are included with the sensor. Other tools will need to 
be provided. 

Table 1  Installation

Tools Needed

Wrench  13 mm (0.5 in) 

Flathead screwdriver

Mounting post  33.0 to 53.3 mm (1.3 to 2.1 in) diameter post, pole, tripod, 
tower, or other similar infrastructure that extends above the canopy

Mounting b leveling plate  Model AL-120 (included).

Nylon screw  #10-32 x 3/8 in (included)

METER ZENTRA series data logger  ZL6 or EM60

METER ZSC Bluetooth

®

 Sensor Interface (optional)

METER ZENTRA software  ZENTRA Utility, ZENTRA Utility Mobile, or 

ZENTRA Cloud

Summary of Contents for APOGEE SU-221

Page 1: ...APOGEE UV SENSOR...

Page 2: ...CONTENTS 1 Introduction 2 2 Installation 2 2 1 Set Up Mounting Assembly 4 2 2 Connect to METER ZENTRA Series Logger 5 3 Data Interpretation 6 4 Troubleshooting 6 5 Customer Support 7 Index 8 18443 00...

Page 3: ...1 p a g e e I N S T R U M E N T S Made in USA...

Page 4: ...y before going out to the field For more information on Apogee sensors please review the Ultraviolet A Radiation Sensor User Manual or visit the Apogee UV sensor product page apogeeinstruments com uv...

Page 5: ...Northern hemisphere or true South in the Southern hemisphere to reduce azimuth error Secure the System Tighten the U bolt nuts by hand until hand tight and then tighten with a wrench CAUTION Do not ov...

Page 6: ...ensor M8 connector holes and seat connectors fully 2 Tighten the cable screw until hand tight Figure 1 M8 connectors are easy to overtighten Do not use pliers or other tools to tighten this connector...

Page 7: ...data loggers 1 Plug the stereo plug connector into one of the sensor ports on the logger Figure 4 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 TEST OK ERROR Conduit Figure 4 Logger connection 2 Connect t...

Page 8: ...not responding Check power to the sensor and logger Check sensor cable and stereo plug connector integrity Check that the SDI 12 address of the sensor is 0 factory default Check this with ZENTRA Util...

Page 9: ...Customer support representatives are available for questions problems or feedback Monday through Friday 8 00 to 17 00 Central European time Email support europe metergroup com sales europe metergroup...

Page 10: ...I installation mounting 3 4 preparation 3 tools needed 2 M mounting 3 mounting bracket 2 4 R recalibration 6 S stereo plug connector 5 T troubleshooting 6 U U bolt 3 4 ultraviolet radiation 2 4 user m...

Page 11: ...ins Court Pullman WA 99163 T 1 509 332 2756 F 1 509 332 5158 E info metergroup com W metergroup com METER Group AG Mettlacher Stra e 8 81379 M nchen T 49 89 1266520 F 49 89 12665220 E info europe mete...

Page 12: ......

Reviews: